Do you have a question about the Cp3800 and is the answer not in the manual?
Questions and answers
David Stone
March 27, 2025
Hello , My Lx3800 uses a 110 feed for the power center I see it terminates on #2 & #3 manual shows a black / black- blue and Black- yellow My Transformer has a Black a Yellow and a purple wire for the 110 system hookup. Are two of the wires on terminal 2? and the black on terminal 3. Thanks for your help.
1 comments:
Mr. Anderson
May 14, 2025
For a 110V feed system using the Compool Cp3800 Power Center:
1. At the sub-panel, install a circuit breaker. 2. Run the hot (line) wire from the circuit breaker to LINE 1 on the relay terminal block. 3. Connect a neutral wire to LINE 2 on the relay terminal block. 4. Connect the equipment to LOAD 1 and LOAD 2 on the same relay. 5. If the pump is greater than 3 H.P., use an external contactor and let the relay switch the contactor coil.
Ensure proper grounding and follow electrical codes.
Need help?
Do you have a question about the Cp3800 and is the answer not in the manual?
Questions and answers
Hello , My Lx3800 uses a 110 feed for the power center I see it terminates on #2 & #3 manual shows a black / black- blue and Black- yellow My Transformer has a Black a Yellow and a purple wire for the 110 system hookup. Are two of the wires on terminal 2? and the black on terminal 3. Thanks for your help.
For a 110V feed system using the Compool Cp3800 Power Center:
1. At the sub-panel, install a circuit breaker.
2. Run the hot (line) wire from the circuit breaker to LINE 1 on the relay terminal block.
3. Connect a neutral wire to LINE 2 on the relay terminal block.
4. Connect the equipment to LOAD 1 and LOAD 2 on the same relay.
5. If the pump is greater than 3 H.P., use an external contactor and let the relay switch the contactor coil.
Ensure proper grounding and follow electrical codes.
This answer is automatically generated