C. Diagnosis Code Table
Code
Abnormality/Protection
H11
Indoor/Outdoor abnormal
communication
H14
Indoor intake air temp sensor
abnormality
H15
Outdoor
compressor
sensor abnormality
H16
Outdoor current transformer
open circuit
H19
Indoor fan lock
H23
Indoor heat exchanger
temperature A sensor
H24
Indoor heat exchanger
temperature B sensor
H25
Air filter abnormality
H27
Outdoor air temperature sensor
abnormality
H28
Outdoor heat exchanger
temperature sensor
abnormality
H30
Discharge temperature sensor
abnormality
H33
Incorrect connection of
Indoor/Outdoor cable
H97
Outdoor fan motor lock
H98
Indoor high pressure
protection
H99
Indoor heat exchanger
anti-freezing protection
F11
Cooling/heating cycle
change over abnormality
F16
Cooling/Dry cycle changeover
abnormality
F90
PFC control
F91
Refrigeration cycle abnormality
F93
Compressor abnormality
F95
Cool high pressure protection
F96
IPM overheating protection
F97
Outdoor
compressoroverheating
protection
F98
Total running currentprotection
F99
Outdoor
Peak
Control
Judgment
>1minute after
starting
operation
-
temperature
Continue for 5
sec.
-
-
Continue for 5
sec
Continue for 5
sec
-
Continue for 5
sec
Continue for 5
sec.
Continue for 5
sec.
-
Twice within
20 sec.
-
Indoor heat
exchanger
freezing
4 times occurrence
within 30 minutes
4 times occurrence
within 30 minutes
4 times occurrence
within 20 minutes
2 times occurrence
within 20 minutes
4 times occurrence
within 20 minutes
4 times occurrence
within 20 minutes
-
4 times occurrence
within 20 minutes
3 times occurrence
within 20 minutes
CurrentProtection
4 times occurrence
continuously
30 minutes
www.ilmalämpöpumput.com
Check
Connecting cable, Indoor /outdoor PCB
Intake air temperature sensor
( defected or disconnected)
Compressor temperature
sensor(defected or disconnected)
Outdoor PCB, IPM module
Indoor PCB, fan motor
Heat exchanger temperature sensor
(defected or disconnected)
Heat exchanger temperature sensor B
(defected or disconnected)
Outdoor temperature sensor
(defected or disconnected)
Outdoor heat exchanger sensor
(defected or disconnected)
Discharge temperature sensor
(defected or disconnected)
Indoor/outdoor supply voltage
Outdoor fan motor
Air filter dirty
Air circulation short circuit
Insufficient refrigerant
Air filter dirty
4-way valve
V-coil
Indoor PCB
Voltage at PFC
No refrigerant(3-way valve is closed)
Compressor
Outdoor refrigeration cycle
Excessive refrigerantImproper heat radiationIPM X
Insufficient refrigerantCompressor
Excess
refrigerantImproper
PCBIPMCompressor
within
33
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Emergency
Operation
O
X
X
X
X
O
O
O
O
O
O
X
X
-
-
X
X
X
X
X
X
X
radiationOutdoor
X
X

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-pe9ckeCs-pe12ckeCu-pe12cke

Table of Contents