B.Angular Speed of Vertical Vane
Airflow Direction Changes or Vertical Airflow Vane Closes
Swings Up and Down (Auto Airflow Direction)
C. Mode Judgement for Auto Operation
Airflow Mode Setting
Initializing When Power-On
Auto Operation
Shifted to Auto Mode
Note:
When the air-conditioner is turned on, if manual airflow direction is selected and the angle is lower than the lower limit
for heating operation, the airflow direction will be changed to the lower limit for heating mode. If Cooling operation is
determined during the mode judgement, the airflow direction will be shifted to lower limit for cooling operation.
D. About Timer-Setting
During On-Timer operation, the airflow direction can be changed between Manual and Auto.
Auto
Upper Limit
Upper Limit
Same to Cool/Dry/Heat
www.ilmalämpöpumput.com
31
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Vertical Airflow Vane
22.06/s
2.21~5.52/s
Manual
Lower Limit
Position Previously Set
Same to Cool/Dry/Heat