Blower; Blower Duct Connection - FireplaceXtrordinair 44 Elite-ZC Installation Manual

Zero clearance fireplace
Table of Contents

Advertisement

Blower

The external blower pushes air through blower duct to the fireplace, where it is heated and
distributed into the room. The blower may be located to draw air from the exterior of the home,
producing positive pressure inside the home. Or, if desired, the blower may be located to draw
air from the interior of the home.
Exterior
Fireplace
Interior of Home
Do not draw air from confined areas or from
a garage or area containing fumes or
emissions. The blower inlet must be a
minimum 36" below any exhaust vent.
The blower may be installed to draw air from
a crawl space or attic if approved by local
building codes. NOTE: certain codes
require a fire curtain in these cases.

Blower Duct Connection

The shorter the blower duct, the
greater the air flow.
Connect the blower duct to the
right, left, or bottom of the
fireplace. Each location is
sealed with a cover plate (use a
5/16" nutdriver to remove cover
plate). If using the bottom
location, remove the 8-1/2" by
6-1/4" air deflector directly
above the cover plate and attach
the duct to the 6" hole above the
deflector. Insert the starter
section into the blower hook-up
hole and bend the flanges
outwards, locking the starter
section in place.
Attach the flex duct to the collar on the blower box and start collar using duct tape and/or screws
The maximum length for 6" diameter blower duct is 15' (use the included duct & start collar)
Internal Blower
Exterior Wall
TOP
VIEW
Conduit Cover Plate
(On both sides)
I
NSTALLATION
Exterior
Exterior Wall
Ring for
duct
11-3/8"
6"
Hole for
Conduit
1-1/2"
Fireplace
Xtrordinair
6" Blower
Hook-Up
(C
ONTINUED
External Blower
Fireplace
Interior of Home
The blower may be placed
in a ventilated crawl space
(if approved by the local
building department).
Height: 13"
FRAMING
Width: 11-3/8"
DIMENSIONS:
Depth: 11-1/2"
Snap conduit
connector into the
hole in the top of
the blower housing.
Wire
Plugs
Locking Tabs
Start Collar
Blower
Housing
Flex Duct
Min. 4"
11 1/2"
)
P
11
AGE
13"
Intake grill
must be
accessible.
Power Source
(120 Volt A.C.)