Clamp-Up Limit Switch Adjustment (Models: A And Aep) - Challenge SPARTAN 185 Service Manual

Automatic aper cutter spartan 185 sa/a/aep
Table of Contents

Advertisement

Make necessary adjustments by turning the Sequence Adjustment Screw (Figure 16) located on the
electrical panel (See Section 3.4 Accessing the Electrical Panel, page 12).
CCW
Sequence Adjustment Screw

3.5.11 Clamp-Up Limit Switch Adjustment (Models: A and AEP)

The clamp-up limit switch determines where the clamp stops in the "up" position. If the clamp stops
too high or too low, adjust as follows:
1. Turn off the power and disconnect the power cord.
from the limit switch with out disconnecting power could cause the clamp motor to
inadvertently start up and cause severe injury. It is extremely important to disconnect power
while making this adjustment.
2. Remove and disconnect the display panel, then remove the top cover.
3. MAKE SURE POWER IS DISCONNECTED (see caution above) and manually move the
clamp down by first disengaging the motor brake (Figure 17), and then rotating the drive belt
or pulleys by hand.
Engage Brake
CW
Figure 16
Attempting to adjust this limit switch or to move the clamp away
Disengage Brake
Figure 17
Drive Belt
3.0 Maintenance Guide