5924 001
SDK Appli Display
5930
[Meter Click Ch.] Meter Click Charge
5930 001
Meter Click Ch.
5930 010
PCU
5930 014
Mid Trans Unit
5930 016
Fusing Unit.
5990
[SP Print Mode]
5990 001
All (Data List)
5990 002
SP (Mode Data List)
5990 004
Logging Data
5990 005
Diagnosic Report
5990 006
Non-Default
SM
CÓPIA NÃO CONTROLADA
Enables or disables the LCD display of the
SDK application.
*CTL
[0 or 1 / 0 / 1/step]
0: Not display, 1: Display
Enables or disables the Meter Charge mode.
When enabling the Meter Charge mode, the
*EGB
"Counter" menu is added to the user menu.
[0 or 1 / 0 / -]
0: OFF, 1: ON
Displays or does not display the end display
for the PCU. This SP is activated only when
*EGB
the SP5930-001 is set to "1".
[0 or 1 / 0 / -]
0: OFF, 1: ON
Displays or does not display the end display
for the transfer belt unit. This SP is activated
*EGB
only when the SP5930-001 is set to "1".
[0 or 1 / 0 / -]
0: OFF, 1: ON
Displays or does not display the end display
for the fusing unit. This SP is activated only
*EGB
when the SP5930-001 is set to "1".
[0 or 1 / 0 / -]
0: OFF, 1: ON
Does SP5-990-002, 004, 005, 006, and 007.
Prints an SMC report on all SP modes.
Prints an SMC report on the SPs that save
logs.
Prints the Self-Diagnostic Report.
Prints an SMC report on the SPs that have
settings, which are different from the defaults.