50 |
Option
Description
Indicates if network backbone is operating. Check power: Check
Bus State
termination
Rx Overfl ows
Value greater than 0 could indicate the software is very busy and
unable to keep up with incoming messages.
Rx Overruns
Rx Errors
CAN interface error counters. Count up when there are errors on
the CAN bus, and down when things are ok. Should normally be
0. Goes bus off when 255 is reached. Check same things as for Bus
Tx Errors
state if greater than 0 observed
Detected errors since power up. Check the network if this is
Fast packet Errors:
continually increasing.
Rx Messages
A count since power up of messages received / transmitted.
Tx Messages
Bus Load
Real time bus load in percentage of max capacity
SimNet groups
The SimNet Group function is used to control parameter settings, either globally or in groups
of units. The function is used on larger vessels where several SimNet units are connected via
the network. By assigning several units to the same group, a parameter update on one unit
will have the same eff ect on the rest of the group members.
The illustration below shows a two station installation. Units on the bridge have their
backlight and damping settings in diff erent SimNet Groups from the units in the cockpit.
If the back light is adjusted on a display in the cockpit, it will change on all displays in the
cockpit. It will not change the light settings on the bridge. If the damping is adjusted on the
AP80 control unit, this will also aff ect damping on the NSE unit in the remote station.
MAIN BRIDGE
NF80
REMOTE STATION
QS80
System confi guration |
AP70/AP80 Operator Manual
AP80 CONTROL HEAD
CMD
MENU
TURN
STBY
AUTO
NAV
WORK
NSE