6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
Parts name
No.
1
Reactor
Outdoor fan motor
2
Suction temp. sensor (TS sensor)
3
4
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
5
Heat exchanger temp. sensor (TE sensor)
6
Terminal block (5P)
7
8
Compressor
9
COIL FOR P.M.V.
10
Coil for 4-way valve
Type
DC 340V, 30W
ICE-340-30-4
( - )
10kΩ at 25°C
( - )
10kΩ at 25°C
24BYJ48-HTP
Output (Rated) 1W, 16 poles, DC12V
Model name
CH-57 x 2 PCS
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
DA108X1C-23FZ
CAM-MD12TCTH-5
SQ
− 18 −
FILE NO. SVM-13027
Specifications
Rating
L = 10mH, 16A
DC140V, 43W
10k Ω (25°C)
62k Ω (20°C)
10k Ω (25°C)
10k Ω (25°C)
30A, AC600V
3-phases 4-poles 750W
DC12V
AC220-240V