Toshiba RAS-167SKV-E5 Service Manual page 27

Split type high wall, heat pump type
Hide thumbs Also See for RAS-167SKV-E5:
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ ˚C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Fan speed
COOL
HEAT
level
WF
UH
WE
H
WD
UH
M+
WC
H
WB
M+
M+
WA
W9
M
L+
W8
L
W7
L+
L-
W6
L
W5
L-
UL
W4
UL
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WB)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*4
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W6)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-167SKV-E5
DRY
Fan speed
Air flow rate
(rpm)
(m3/h)
1470
743
1470
743
UH
1440
723
H
1390
691
M+
1250
601
M
1190
563
1120
518
970
421
L+
950
408
L
890
370
L-
870
357
UL
810
318
SUL
750
280
600
183
500
119
(Fig. 1)
Fan speed
W6
(L + M) / 2
W9
(M + H) / 2
WC
(Fig. 2)
RAS-16EKV-EE
Fan speed
Air flow rate
(rpm)
(m3/h)
1470
743
1470
743
1440
723
1390
691
1250
601
1190
563
1120
518
970
421
950
408
890
370
870
357
810
318
750
280
600
183
500
119
– 27 –
FILE NO. SVM-13027
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.

Hide quick links: