10-3-4. Wiring connection
CAUTION
<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing of the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward
you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local
cords) into the pipe hole on the wall.
4. Take out the connecting cable through the cable
slot on the rear panel so that it protrudes about
15 cm from the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air
inlet grille on the indoor unit.
CAUTION
• Be sure to refer to the wiring system diagram
labeled inside the front panel.
• Check local electrical cords and also any specific
wiring instructions or limitations.
Cord clamp
Terminal cover
Screw
Screw
Screw
Connecting cable
Stripping length of the connecting cable
NOTE :
Use stranded wire only.
Wire type : More than H07RN-F or 60245 IEC66
(1.0 mm
2
or more).
<How to install the air inlet grille on the indoor unit>
When attaching the air inlet grille, the contrary of the
removed operation is performed.
Terminal block
Earth line
Connecting cable
110 mm
Earth line
10 mm
10 mm
50 mm
10-3-5. Piping and drain hose installation
<Piping and Drain Hose Forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
1. Die-cutting Front panel slit
Cut out the slit on the leftward or right side of the front
panel for the left or right connection and the slit on the
bottom left or right side of the front panel for the
bottom left or right connection with a pair of nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection
and rearleftward connection's piping, it is necessary to
change the drain hose and drain cap.
<How to remove the Drain Cap>
Clip the drain cap by needle-nose pliers and pull out.
<How to remove the drain hose>
The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
To install the drain hose, insert the drain hose firmly
until the connection part contacts with heat insulator,
and the secure it with original screw.
Heat insulator
Drain hose
– 51 –