Electrical Requirements - Emerson CF620AP00 Owner's Manual

52” wet location ceiling fan laguna bay
Table of Contents

Advertisement

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.
WARNING
!
To reduce the risk of fire, electrical shock, or
personal injury, mount fan to outlet box marked
"Acceptable for Fan Support of 22.7 kg. (50 lbs.) or
less", and use screws supplied with outlet box. Most
outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.
How to Put Your Ceiling Fan Together
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
1. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the clevis pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 5.
2. Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80" motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupling. Install the
clevis pin and secure with the hairpin clip (Figure
2). The clevis pin must go through the holes in the
motor coupling and the holes in the downrod. Be
sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the clevis
pin is properly installed.
WARNING
!
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

Electrical Requirements

!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
!
To avoid fire or shock, follow all wiring instructions
carefully. Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.
PIN
HANGER
BALL
DOWNROD
Figure 1
SETSCREW (2)
SETSCREW
CLEVIS PIN
CLEVIS PIN
Figure 2
4
WARNING
WARNING
SETSCREW
DOWNROD
DOWNROD
HAIRPIN
HAIRPIN
CLIP
CLIP
MOTOR
MOTOR
COUPLING
COUPLING
U.L. Model No.: CF620

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf620aw00Cf620vnb00

Table of Contents