S 3Xx; S 4Xx; Cap Assembly; Figure 5-7: S 25X Cap Assembly - Miele S 247i Technical Manual

Table of Contents

Advertisement

Technical Information
3. Release the indicator from the lid.
Note:
Do not unscrew the lacquered screw as this is used to adjust the indicator.
If the indicator needs to be dismantled then the indicator disc must first be
turned to the right as far as possible.
5.5.3

S 3xx

1. Open the accessory compartment lid.
2. Unscrew the 2 Phillips screws securing the indicator to the lid.
3. Remove the indicator from the lid.
5.5.4

S 4xx

1. The accessory compartment lid catch and the dustbag change indicator
form one part.
2. Unscrew the retaining screw and remove the part.
3. When re-installing, ensure that the lid opener spring is correctly located.
5.6

Cap Assembly

5.6.1
S 25x
1. Remove the dust compartment lid (Section 5.1).
2. Remove the 2 Phillips screws securing the cap assembly to the base.
3. Lift up the cap assembly and pull forward to remove it from the base.

Figure 5-7: S 25x Cap Assembly

Note:
Before installing the cap assembly (Figure 5-7, Item 1) the end strip (Item
2) must be removed. Attach the assembly with the screws (Figure 5-10,
Item 2), then clip on the end strip (Figure 5-7, Item 2), while pressing
down on the switch cover. Take care not to trap any wires.
5.6.2
S 27x
1. Remove the rear casing (Section 5.7).
2. Remove the 2 Phillips screws securing the trim piece.
S 2xx, S 3xx & S 4xx Canister Vacuums