1. Remove the cap assembly (Section 5.6).
2. Take off the rotary dial (pry off with a small screwdriver, if necessary).
3. Remove the Phillips screw.
4. Use a small screwdriver to release the spade connections from the white
terminal block (mark/tag all connections before disconnecting them!).
5. Release the overheat light and potentiometer from the cap assembly.

Figure 5-20: Rotary Potentiometer, S 3xx

Figure 5-21: Slide Potentiometer, S 3xx