20
TEST THE SAFETY REVERSE SYSTEM
The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle
laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing
garage door. Repeat test once a month and adjust as needed.
Procedure: With door opened place a 40 mm obstacle (1)
laid flat on the floor under the garage door. Operate the
door in the down direction. The door must reverse off the
obstacle. If the door stops on the obstacle, remove obstacle
and repeat Program the Limits and Force Steps, then
repeat safety reverse test.
When the door reverses off the 40 mm obstacle, remove
the obstacle and run the opener through a complete travel
cycle. Door must not reverse in closed position. If it does,
repeat Program the Limits and Force then repeat safety
reverse test.
21
PROGRAM THE TRAVEL SPEED (OPTIONAL)
TRAVEL SPEED: Automatically selected:
There are two travel speeds available for this opener.
The speed is a function of door travel distance and is automatically set during the door travel limit setting process.
* Travel distance longer then 2 metres = REGULAR speed
* Travel distance shorter than 2 metres = SLOW speed
TRAVEL SPEED: Manually selected:
The speed can be set manually if required, once the travel limits have been set, using the following method.
To activate the alternate speed:
PRESS and HOLD both the UP and DOWN arrows for 3 seconds.The courtesy lamp will flash once to confirm SLOW
speed and twice to confirm REGULAR speed.
22
PROGRAM THE LOW STANDBY MODE (OPTIONAL)
Low Standby Mode (sub 1 watt) is activated by the factory to deliver the lowest possible standby power.
In this mode the External Accessories Power and the IR Beams are turned OFF when the door is closed and the courtesy light
is OFF.
At mains turn ON: Courtesy light flashes 2 times = Low Standby Mode
Courtesy light flashes 10 times = Normal Standby Mode
The Normal Standby Mode will need to be activated for External Accessories Power.
To Activate Normal Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the UP and DOWN arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 10 flashes.
Release the arrow buttons.
To Activate Low Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the UP and DOWN arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 1 flash.
Release the arrow buttons.