Summary of Contents for Chamberlain PowerLIft CS110MYQ
Page 1
chamberlaindiy.com.au chamberlaindiy.co.nz CS110MYQ MyQ App Controlled Sectional Garage Door Opener Installation and Operating Instructions Owners Copy: SAVE THESE INSTRUCTIONS for future reference This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY...
400 N (40 kgf). Excessive force will interfere with the proper before installing this opener. operation of the Safety Reverse System or damage the garage SPECIAL NOTE: Chamberlain strongly recommends that door. Do not wear rings, watches or loose clothing while Safety Beams be installed on all garage door openers.
BEFORE YOU BEGIN: 1. Look at the wall and ceiling above the garage door. (The opener and header bracket must be securely fastened to structural supports.) 2. Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware (not supplied) may be required.
RAIL DIMENSIONS DOOR HEIGHT: BELT & RAIL RAIL LENGTH: CEILING FIXING Sectional Doors PART NUMBER: POINTS: Up to 2.2 m 8422 CR5 3000 mm segmented 2840 mm NOTE: The Ceiling Fixing Point is measured back from the header bracket (see item 1 to 7 of “completed installation”). Also allow 400 mm back from the fixing point for installation of the powerhead (item 7 to 9 of “completed installation”).
Common terminal for push button Ground White Common terminal for Safety Beams Safety Sensor Gray Chamberlain Safety Beam Input: (pulsing type only) Door-in-door Green For Door in Door dry contact sensor: (see note below) Door-in-door Green Common terminal for Door in Door sensor (4&5 are...
ASSEMBLY SECTION ASSEMBLING THE 4 PIECE SEGMENTED RAIL The segmented rail is largely preassembled and consists of 4 parts. The carriage, push rod, release handle, the guide pulley and the lintel bracket with belt tensioner are in the front part (A). The seating for the drive shaft and the sprocket are in the rear part (B).
INSTALLATION SECTION Wear protective goggles when working overhead to protect your eyes from injury. Disengage all existing garage door locks to avoid damage to the garage door. To avoid serious personal injury from entanglement, remove all ropes connected to the garage door before installing the opener.
Page 8
POSITION THE OPENER Disengage the trolley mechanism (see section “Operating the manual release”) and slide it back towards the powerhead. Secure the hanging push arm up into the rail assembly temporarily using tape or rope, to avoid a hazard. SECTIONAL DOOR You will need a 50 mm piece of timber or similar spacer to gauge the distance between door and rail.
Page 9
HANG THE OPENER The opener must be securely fastened to a sound structural support above the opener. fig.1 1.Postion the opener as in the previous step. Check the rail is centred over the door. Ensure the rail brackets (fig.1) is on the Powerhead end of the rail in a position as close to the opener as possible (X).
Make sure the garage door is fully closed. Pull the manual release ATTACH DOOR ARM TO TROLLEY cord to disengage the trolley. Slide the trolley to around 300 mm Fig. 1 Fig. 2 from the header bracket. 1.The straight door arm is already preassembled to the trolley. 2.Install the curved arm onto the door bracket using the Clevis pin (2) and R-Clip (3) supplied.
ADJUSTMENT SECTION Travel limits regulate the points at which the door will stop PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS Without a properly installed safety reversal when moving UP or DOWN. The travel limit buttons are located system, persons (particularly small children) under the access cover on the rear panel (fig.
TEST THE SAFETY REVERSE SYSTEM The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing garage door.
100 mm above the floor. bottom of the door is over 400 N (40 kgf). Disconnect power to the garage door opener SPECIAL NOTE: Chamberlain strongly recommends that before installing Safety Beams. Safety Beams be installed on all garage door openers.
Page 14
SAFETY BEAMS (CONTINUED) Connect cable to the Opener: fig. 3 Disconnect the mains Power from the Opener. Cable tie mount At the Powerhead Control Panel, pass both sets of cabling through the top panel access hole. Cable routing along the top of the rail to the opener. Twist both WHITE wires together and both BLACK wires together.
To prevent possible serious injury/death, or property damage read and follow all instructions carefully. • The Internet Gateway System: is designed to operate with Chamberlain Sectional and Rolling Garage Door openers, and all the SAFETY INSTRUCTIONS detailed in the OPENER HANDBOOK need to be observed.
Page 16
• When the Chamberlain Internet Gateway powers up, the GREEN LED and BLUE LED will blink 3 times to indicate a correct power connection and reset of the Internet Gateway. After power up, the LEDs will indicate the status of the Chamberlain Internet Gateway.
Page 17
Step 3 - Getting A Smartphone App If you have an older OS, the phone or tablet will not be able to locate the Chamberlain MyQ ® app. You may need to upgrade the phoneʼs OS to be able to find, download, and use the Chamberlain MyQ app.
Page 18
Go to Places tab > Menu button > Manage Places screen. Select your place (Chamberlain Internet Gateway) To Add: To Add: - Tap the Chamberlain Internet Gateway name - Menu button > Add New Device - Tap Add New Device - Then follow instructions To Delete:...
Page 19
• The GREEN LED must be on continuously after power and network connections are completed (NOTE: The LED may blink intermittently with data traffic). • GREEN LED Off – The router is not providing an IP address to the Chamberlain Internet Gateway. Check your router settings and internet connections.
TIMER TO CLOSE FEATURE (TTC) Door may operate unexpectedly, therefore do not allow anything to stay in the path of the door. fig. 1 The Timer to Close feature requires Safety Beams to be installed. Indicator LED Operation: This feature allows the door to automatically close from a fully open position after a specified time.
INSTALL WARNING LABELS chamberlaindiy.com.au chamberlaindiy.co.nz For Service Call RISK OF ENTRAPMENT Installation Date Repeat Safety Reverse Test monthly. Door 114A3361 must reverse on contact with a 40mm obstacle For Service Call placed on the floor. Make necessary adjustments. AUTOMATIC DRIVE: Keep away from the area of the door since it may operate unexpectedly.
WIRELESS PROGRAMMING (OPTIONAL ACCESSORIES) Activate the opener only when door is in full view, free of obstruction and properly adjusted. No one should enter or leave garage while door is in motion. Do not allow children to operate push button(s) or remote(s). Do not allow children to play near the door.
MAINTENANCE AND CARE OF YOUR OPENER Battery of the remote control: USING YOUR OPENER REPLACE BATTERIES IN REMOTES 1. Your opener can be activated by any of the following devices: • Opener control panel: Up and Down Buttons. The batteries in the remote have an extremely long life. •...
TROUBLE SHOOTING 1. Opener doesn't operate from either door control or 7. Door opens but won't close: remote: • Check Safety Beams. If the light on the Beams are • Does the opener have electric power? Plug lamp into flashing, correct the alignment. outlet.
Page 25
DIAGNOSTIC CHART Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage opener flash the diagnostic codes. DIAGNOSTIC CODE SYMPTOM POSSIBLE RESOLUTION UP Arrow DOWN Arrow Flash(es) Flash(es) The garage door opener will not Safety sensors wires may have been reversed, cut or disconnected.
SPECIFICATIONS - PowerLift MyQ - CS110MYQ IInput Voltage......230-240 Vac, 50 Hz Max. Pull Force ......1000 N Power ........225 Watt Standby Power ......0.8 Watt (door fully closed) Normal Torque ......7 Nm Max door weight......130 kg Max lift under spring tension ..20 kg Max door area......Sectional doors 16 m Motor Type..........DC gearmotor permanent lubrication...
Unit to you. and support for our goods and are pleased to provide you, the original This Chamberlain Limited Warranty does not cover any failure of, or defect in, purchaser, with this Chamberlain Limited Warranty.