Horizontal runs may have a 0" rise per foot however for optimum performance it is recommended that all hori-
zontal runs have a minimum 1/4" rise per foot using flexible or rigid venting. For safe and proper operation of
the fireplace, follow the venting instructions exactly.
When terminating vertically, the vertical rise is a minimum 3 feet and a maximum 40 feet from the top of the
fireplace.
fIgure 2.1.1
19 1/2" min
38"
tp - vent lengths
tp - periscope termination
W415-0750 / 12.17.08
24" max
57 1/2"
min
plus
rise
fIgure 2.1.2
38"
16" min
40ft
max
3ft
min