BLOWER PACKS

All Atmospheric Humidifiers
Installation,
Troubleshooting, and
Exploded Views
IMPORTANT: Read and save this guide for future
reference. This guide to be left with equipment owner.
Form #07-239
1506261

Advertisement

Table of Contents
loading

Summary of Contents for Nortec BLOWER PACKS

  • Page 1: Blower Packs

    BLOWER PACKS All Atmospheric Humidifiers Installation, Troubleshooting, and Exploded Views IMPORTANT: Read and save this guide for future reference. This guide to be left with equipment owner. Form #07-239 1506261...
  • Page 3: Table Of Contents

    REMOTE MOUNTED BLOWER PACKS - WALL MOUNTING ... . . 1 REMOTE MOUNTED BLOWER PACKS - STEAM LINE ....2 CONDENSATE RETURN LINES .
  • Page 5: Blower Pack Operation

    NHTC & NHPC humidifiers only.) Side Front Wall All blower packs consist of a steel cabinet containing; blower/motor powered by a 115 1” (2.5 cm) Vac single phase supply (208, 277, 440-480 Distributor and 550-600 Vac version available), plastic steam distribution, adjustable air supply.
  • Page 6: Remote Mounted Blower Packs - Steam Line

    Figure #3 Steam Line Installation For GS, SE, and NH Series using large size remote mounted blower packs (>50 lbs/hr) Remote mounted Blower pack use 1 5/8” O.D. (Nominal 1 ½”) copper tubing. For steam runs longer then 20 ft, use insulated nominal 2”...
  • Page 7: Condensate Return Lines

    PRIMARY VOLTAGE CONNECTION See Figure #5. All blower packs for SE and GS unit are 12. Do not run the steam line more than 1 foot wired by others to be powered by an per lb/hr output.
  • Page 8: Primary Voltage Supply Wiring From Humidifier(S) To Blower Pack

    PRIMARY VOLTAGE SUPPLY WIRING FROM HUMIDIFIER(S) TO BLOWER PACK All blower packs are wired by factory if built-on, and to be powered from the humidifier. All built-on blower packs are factory wired to the humidifier.
  • Page 9: Blower Pack Clearances And Dimensions

    Overhead And Frontal Clearances For Blower Packs Model Min. No. Of Min. Overhead Min. Front Blower Clearance Clearance Packs Inches (cm) Inches (cm) 18 (45) 30 (76) 18 (45) 30 (76) 18 (45) 36 (91) 18 (45) 72 (183) 36 (91)
  • Page 10: Exploded View Of The Blower Pack

    EXPLODED VIEW OF THE BLOWER PACK NOTE: ITEMS 30 AND 31 NOT SHOWN. ITEM 30 CAN REPLACE ITEM 18 AND ITEM 31 CAN REPLACE ITEM 10 IN DIFFERENT WORKING CONFIGURATIONS. Blower Packs Installation and Exploded Views - 6 -...
  • Page 11 OPTIONAL BLOWER PACK REPLACEMENT PARTS FOR NH, SE, GS models Item Part Number Description 2522174 Cabinet, Shell, Blower Pack 1473002 Terminal Block 2 Pole - WECO P/N 327-FU 1323020 Ground Clamp 1323082 Terminal Strip 2 Pole 2522070 Relay 30A 115V SPDT 1453055 Fuse Holder for MDA, S.O Term 2524202...
  • Page 13: Limited Warranty

    Any further warranty must be in writing, signed by an officer of THE COMPANY. THE COMPANY’s limited warranty on accessories, not of AXAIR NORTEC’s manufacture, such as controls, humidistats, pumps, etc. is limited to the warranty of the original equipment manufacturer from date of original shipment of humidifier.
  • Page 15 - www.humidity.com - U.S.A. - AxAir NORTEC Inc. 826 Proctor Avenue, Ogdensburg, New York, 13669 CANADA - AxAir NORTEC Ltd. 2740 Fenton Road, Ottawa, ON, K1T 3T7 1-(866) NORTEC-1 Fax - (613) 822-7964 A WMH COMPANY...