Safety Controls; Figure 10. Gear Motor Thermal Overload - Cornelius WM600 Installation & Owner's Manual

Ice maker
Hide thumbs Also See for WM600:
Table of Contents

Advertisement

10. Check or replace run capacitor (if supplied) check or shorted capacitor or either terminal grounded to case.

SAFETY CONTROLS

Your Icemaker unit has several safety and control devices incorporated into its design.
WARNING: None of the below described devices should ever be "bypassed" to allow the
unit to function.
The safety and control system shut–off devices are:
1. Low water shut off reed switch located in icemaker float assembly. (Automatic reset type).
2. Gear motor thermal overload, manual reset type (red button on motor). See Figure 10.
3. Compressor thermal overload, automatic reset type.
4. Main service switch located on top of the control box.
5. Hopper shut–off.
6. High pressure cut out (water cooled only).
WARNING: Do not reset gear motor overload if ice is present in the evaporator.

FIGURE 10. GEAR MOTOR THERMAL OVERLOAD

17
630460082