Lincoln Electric Eagle 10,000 Plus Operator's Manual page 18

Lincoln electric eagle 10,000 plus welder and generator
Table of Contents

Advertisement

B-2
"
RANGE" SWITCH
The "Range" switch is used to select one of four
amperage ranges with generous overlap for Stick/TIG
welding.
Process
Range Setting
STICK/TIG
90 Max.
(Constant current)
145 Max.
(3 range settings)
225 MAX.
CAUTION
Never change the "RANGE" Switch setting while
welding. This will damage the switch.
------------------------------------------------------------------------
"
CONTROL" DIAL
Provides a fine welding current adjustment within the
Range Switch settings in the STICK mode and weld-
ing voltage control with the Range switch set in the
wire feed mode.
EAGLE™ 10,000 PLUS APPROXIMATE FUEL CONSUMPTION
Low Idle - No Load
2400 RPM
High Idle - No Load
3700 RPM
DC CC Weld Output
210 Amps @ 25 Volts
Auxiliary Power
9000 Watts
OPERATION
Current Range
40 to 90 Amps
70 to 145 Amps
120 to 225 Amps
KOHLER
23 H.P. COMMAND CH23S, CH680
.40 Gallons/Hour
(1.50 Liters/Hour)
.7 Gallons/Hour
(2.8 Liters/Hour)
1.3 Gallons/Hour
(4.9 Liters/Hour)
1.4 Gallons/Hour)
(5.3 Liters/Hour)
EAGLE™ 10,000 PLUS
KOHLER
23 H.P. COMMAND CH730
.41 Gallons/Hour
1.6(Liters/Hour)
.9 Gallons/Hour
3.5(Liters/Hour)
1.5 Gallons/Hour
5.7(Liters/Hour)
1.7 Gallons/Hour)
6.4(Liters/Hour)