Copy Adjustments
Registration: Platen Mode
1.
Place the test chart on the exposure glass and make a copy from one of the feed
stations.
2.
Check the leading edge [A] and side-to-side [B] registration, and adjust them with the
following SP modes if necessary.
Leading Edge
Side-to-side
Magnification
Use the S5S test chart to perform the following adjustment.
Sub Scan Magnification
D009/D011/D012/D013/D091/D092
SP No.
SP4-010-1
SP4-011-1
4-102
Specification
0 ±2.0 mm
0 ±2.5 mm
SM