Specifications; Standard Type - FujiFilm MEH531 Brochure

Frenic multi series high performance compact inverters
Table of Contents

Advertisement

Specifications

●Standard type
■Three-phase 230V (1/8 to 20HP)
Item
Type (FRN
E1S-2U)
Applicable motor rating [HP] (*1)
Rated capacity [kVA] (*2)
Rated voltage [V] (*3)
Rated current [A] (*4)
Overload capability
Rated frequency [Hz]
Phases, voltage, frequency
Voltage/frequency variations
Rated current [A] (*9)
Required power supply capacity [kVA] (*5)
Torque [%] (*6)
Torque [%] (*7)
DC injection braking
Braking transistor
Applicable safety standards
Enclosure (IEC60529)
Cooling method
Weight / Mass [lbs(kg)]
■Three-phase 460V (1/2 to 20HP)
Item
Type (FRN
E1S-4U)
Applicable motor rating [HP] (*1)
Rated capacity [kVA] (*2)
Rated voltage [V] (*3)
Rated current [A] (*4)
Overload capability
Rated frequency [Hz]
Phases, voltage, frequency
Voltage/frequency variations
Rated current [A] (*9)
Required power supply capacity [kVA] (*5)
Torque [%] (*6)
Torque [%] (*7)
DC injection braking
Braking transistor
Applicable safety standards
Enclosure (IEC60529)
Cooling method
Weight / Mass [lbs(kg)]
■Single-phase 230V (1/8 to 3HP)
Item
Type (FRN
E1S-7U)
Applicable motor rating [HP] (*1)
Rated capacity [kVA] (*2)
Rated voltage [V] (*3)
Rated current [A] (*4)
Overload capability
Rated frequency [Hz]
Phases, voltage, frequency
Voltage/frequency variations
Rated current [A] (*9)
Required power supply capacity [kVA] (*5)
Torque [%] (*6)
Torque [%] (*7)
DC injection braking
Braking transistor
Applicable safety standards
Enclosure (IEC60529)
Cooling method
Weight / Mass [lbs(kg)]
(*1) Fuji's 4-pole standard motor
(*2) Rated capacity is calculated by assuming the output rated voltage as 230V for three-phase 230V series and 460V for three-phase 460V series.
(*3) Output voltage cannot exceed the power supply voltage.
(*4) When setting the carrier frequency (F26) to 3 kHz or less. Use the current (
(*5) Obtained when a DC REACTOR is used.
(*6) Average braking torque obtained when reducing the speed from 60Hz with AVR control OFF (Varies with the efficiency of the motor.)
(*7) Average braking torque obtained by use of external braking resistor (standard type available as option)
Max voltage [V] - Min voltage [V]
(*8) Voltage unbalance [%] =
Three-phase average voltage [V]
If this value is 2 to 3%, use AC REACTOR (ACR: option).
(*9) The value is calculated on assumption that the inverter is connected with a power supply capacity of 500kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50kVA) and %X is 5%.
F12
F25
1/8
1/4
0.3
0.6
Three-phase 200V to 240V (with AVR function)
0.8
1.5
(0.7)
(1.4)
150% of rated current for 1min, 200% - 0.5s
50, 60Hz
Three-phase, 200 to 240V, 50/60Hz
Voltage: +10 to -15% (Voltage unbalance (*8): 2% or less) Frequency: +5 to -5%
(with DCR)
0.57
0.93
(without DCR)
1.1
1.8
0.2
0.3
150
-
Starting frequency: 0.1 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% of rated current
Built-in
UL508C, C22.2No.14, EN50178:1997
IP20, UL open type
Natural cooling
1.3(0.6)
1.3(0.6)
1.5(0.7)
F50
001
1/2
1
1.2
2.0
Three-phase 380V to 480V (with AVR function)
1.5
2.5
150% of rated current for 1min, 200% - 0.5s
50, 60Hz
Three-phase, 380 to 480V, 50/60Hz
Voltage: +10 to -15% (Voltage unbalance (*8): 2% or less) Frequency: +5 to -5%
(with DCR)
0.85
1.6
(without DCR)
1.7
3.1
0.6
1.1
100
Starting frequency: 0.1 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% of rated current
Built-in
UL508C, C22.2No.14, EN50178:1997
IP20, UL open type
Natural cooling
2.4(1.1)
2.6(1.2)
F12
1/8
0.3
Three-phase 200V to 240V (with AVR function)
0.8
(0.7)
150% of rated current for 1min, 200% - 0.5s
50, 60Hz
Single-phase, 200 to 240V, 50/60Hz
Voltage: +10 to -10%, Frequency: +5 to -5%
(with DCR)
1.1
(without DCR)
1.8
0.3
150
-
Starting frequency: 0.1 to 60.0Hz, Braking level: 0 to 100% of rated current, Braking time: 0.0 to 30.0s
Built-in
UL508C, C22.2No.14, EN50178:1997
IP20, UL open type
Natural cooling
1.3(0.6)
) or below when the carrier frequency setting is higher than 4kHz and continuously operating at 100%.
x 67 (IEC 61800-3)
Specifications
F50
001
002
003
1/2
1
2
3
1.2
2.0
3.2
4.4
3.0
5.0
8.0
11
(2.5)
(4.2)
(7.0)
(10)
1.6
3.0
5.7
8.3
3.1
5.3
9.5
13.2
0.6
1.1
2.0
2.9
100
70
40
Fan cooling
1.8(0.8)
3.7(1.7) 3.7(1.7)
Specifications
002
003
005
2
3
5
2.9
4.4
7.2
3.7
5.5
9.0
3.0
4.4
7.3
5.9
8.2
13.0
2.0
2.9
4.9
70
40
150
Fan cooling
3.7(1.7)
3.7(1.7)
5.1(2.3)
Specifications
F25
F50
1/4
1/2
0.6
1.2
1.5
3.0
(1.4)
(2.5)
2.0
3.5
3.3
5.4
0.4
0.7
100
1.3(0.6)
1.5(0.7)
005
007
010
015
5
7.5
10
15
6.8
10
13
19
17
25
33
47
(16.5)
(23.5)
(31)
(44)
14.0
21.1
28.8
42.2
22.2
31.5
42.7
60.7
4.9
7.4
10
15
20
150
5.1(2.3) 7.5(3.4) 7.9(3.6)
13(6.1)
007
010
015
7.5
10
15
10
14
19
13
18
24
10.6
14.4
21.1
17.3
23.2
33.0
7.4
10
15
20
7.5(3.4)
7.9(3.6)
13(6.1)
001
002
1
2
2.0
3.2
5.0
8.0
(4.2)
(7.0)
6.4
11.6
9.7
16.4
1.3
2.4
70
150
Fan cooling
2.0(0.9)
4.0(1.8)
5.3(2.4)
020
20
24
60
(57)
57.6
80
20
16(7.1)
020
20
24
30
28.8
43.8
20
16(7.1)
003
3
4.4
11
(10)
17.5
24.8
3.5