Nilfisk-Advance 21KB Service Manual page 50

Pbu propane floor burnisher
Table of Contents

Advertisement

Service Manual – PBU Propane Floor Burnisher
12. Check the tightness of the throttle cable
clamp. If necessary, tighten the throttle cable
housing clamp screws to firmly secure the
throttle cable housing. Do not over-tighten.
The throttle lever must be able to freely
advance or retract the throttle cable.
13. Move throttle lever to idle position.
Advance the throttle lever fully.
Verify high speed engine RPM is 3500 to
3600.
Move throttle lever to idle position.
Verify low speed engine RPM is 1600 to
1700.
Figure 65 Throttle Cable Housing Clamp Screws
Throttle
Lever in Idle
Position
Figure 66 Throttle Lever in Idle Position, Models without
Clutch
Figure 67 Throttle Lever in Idle Position, Models with
Clutch
Engine System
50
Cable Housing
Clamp Screws
Throttle
Lever in Idle
Position