3.3 PrODUcT SPEcIFIcATIONS

3.3.1 GeNeraTor sPecIFIcaTIoNs

Model
Rated Max. Power ...................................................................5.6 kW**
Surge Power ...............................................................................8400W
Rated AC Voltage .............................................................................230
Rated Max AC Load
Current @ 230V .............................................................24.3 Amps**
Rated Frequency .................................................... 50 Hz @ 3000 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
Model
Rated Max. Power ...................................................................6.4 kW**
Surge Power ...............................................................................9600W
Rated AC Voltage .............................................................................230
Rated Max AC Load
Current @ 230V .............................................................27.8 Amps**
Rated Frequency .................................................... 50 Hz @ 3000 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Battery Type .................................................................... 10 AH, 12VDC
** Operating temperature range: -18° C (0° F) to 40° C ( 104° F). When operating
above 25° C (77° F), there may be a decrease in engine power.
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 305 meters (1,000 feet)
above sea level.

3.3.2 eNGINe sPecIFIcaTIoNs

Displacement ............................................................................... 407cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Part No. ...................................................................0E7585
Spark Plug Gap ........................................................................0.76 mm
Gasoline Capacity ............................................................... 34.07 Liters
Oil Type.................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ............................................ w/ Filter Change = 1.42 Liters
Oil Filter Part No. . ....................................................................070185B
Run Time/Fuel Consumption-1/2 Load .....10 Hours / 3.4 Liters per hour

3.4 GENErAL rEcOMMENDATIONS

The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section of this manual should
be made at least once each season. Follow the requirements in the
"Maintenance Schedule".
12
w/o Filter Change = 1.136 Liters
Once a year replace the spark plug and replace the air filter.
A new spark plug and a clean air filter assure proper fuel-air
mixture, and help the engine run better and last longer.

3.4.1 GeNeraTor MaINTeNaNce

Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors. Cooling air slots in the generator must not become clogged
with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.
Never insert any object or tool through the air cooling
slots, even if the engine is not running.
DO NOT use a garden hose to clean generator. water can enter
the engine fuel system and cause problems. In addition, if water
enters the generator through cooling air slots, some water will
be retained in voids and crevices of the rotor and stator winding
insulation. water and dirt buildup on the generator internal
windings will eventually decrease the insulation resistance of
these windings.

3.4.2 To cLeaN THe GeNeraTor

• Use a damp cloth to wipe exterior surfaces clean.
• A soft, bristle brush may be used to loosen caked on dirt, oil,
etc.
• A vacuum cleaner may be used to pick up loose dirt and debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and openings on the
generator. These openings must be kept clean and unobstructed.

3.4.3 eNGINe MaINTeNaNce

+
when working on the generator, always disconnect
the negative cable from the battery (if equipped). Also
disconnect spark plug wire from spark plug and keep wire
away from spark plug.

3.4.4 cHecKING oIL LeVeL

See the "Before Starting the Generator" section for information on
checking the oil level. The oil level should be checked before each
use, or at least every eight hours of operation. Keep the oil level
maintained.