Electrolux EXI09HD1W Service Manual page 50

Hide thumbs Also See for EXI09HD1W:
Table of Contents

Advertisement

Display Method of Indoor Unit
Indicator Display (during
Malfunction
blinking, ON 0.5s and OFF
Dual-8
NO.
Name
0.5s)
Code
Display
Operation
Indicator
Malfunction of
phase current
44
detection
U1
circuit for
compressor
Malfunction of
voltage
45
U3
dropping for
DC bus-bar
Malfunction
of complete
46
U5
units current
detection
The four-way
47
valve is
U7
abnormal
Zero-
crossing
48
U9
and blink
malfunction of
outdoor unit
Frequency
49
limiting
(power)
Compressor
50
running
The
temperature
51
for turning
on the unit is
reached
Frequency
limiting
52
(module
temperature)
Indicator has 3 kinds of
display status and during
blinking, ON 0.5s and OFF
0.5s
Cool
Heating
Indicator
Indicator
Indicator
OFF 3S
and blink
13 times
OFF 3S
and blink
20 times
OFF 3S
and blink
13 times
OFF 3S
and blink
20 times
OFF 3S
18 times
OFF 1S
and blink
Display Method of Outdoor
Unit
Yellow
Red
Green
Indicator
Indicator
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, the compressor will
stop while indoor fan will
operate;
During heating operating,
the complete unit will stop
operation.
If this malfunction occurs
during
heating operation, the complete
unit will stop operation.
During cooling operation,
compressor will stop while
indoor fan will operate; during
heating,the complete unit will
stop operation.
OFF 1S
and blink
13 times
once
OFF 1S
and blink
8 times
OFF 1S
and blink
11 times
A/C status
Replace outdoor control panel AP1
Supply voltage is unstable
Theres circuit malfunction on
outdoor units control panel AP1,
please replace the outdoor units
control panel AP1.
1.Supply voltage is lower than
AC175V;
2.Wiring terminal 4V is loosened or
broken;
3.4V is damaged, please replace
4V.
Replace outdoor control panel AP1
Possible Causes