5.6 DELAY TIMES

PROTECTOR28
ARMING
When arming the security system by means of the remote controls KR21 or SH624 in the ARM AWAY mode, the system will
arm with a instantaneously (factory default). In case you want to arm the system delayed, you can program the base station
for a delay. (N.B.: Arming the system by means of the ARM AWAY button on the base station, always will result in a delayed
arming of the system).
ALARM SENSORS
When the security system is armed, sensors can activate the system either instantaneously or with a delay. This depends on
the settings of the SC2800 base station and the switch setting of the sensors. Refer to the list below for a complete
overview.
Every time you press a key you hear a short confirmation beep.
1. Set the mode switch to the INSTALL position: All indicators of occupied zones come on
2. Key in your 4 digit PIN code (factory default [0000] refer to 5.8)
3. Press key number 5
4. Press ENTER
5. Press 0 for instantaneous alarm
or
Press 1 for delayed alarm
6. Reset the mode switch to the RUN 1 or RUN 2 position: Zone indicators go out
OVERVIEW DELAY TIME:
SC2800 base station operation "instantaneous alarm"
Arming of the system with remote controls:
Arming of the system with ARM AWAY button of base station:
Arming of the system with ARM HOME button of base station:
Alarm activation by a DS10 door/window contacts:
Alarm activated by an MS10 motion sensors:
SC2800 base station operation "delayed alarm"
Arming of the system with remote controls:
Arming of the system with ARM AWAY button of base station:
Arming of the system with ARM HOME button of base station:
Alarm activation by a DS10 door/window contacts:
Alarm activated by an MS10 motion sensors:
Instantaneous
Delay of one minute
Instantaneous
Instantaneous when switch is in MIN position,
30 seconds when in MAX position
Instantaneous
Delay of one minute
Delay of one minute
Delay of one minute
Instantaneous when switch is in MIN position,
30 seconds when in MAX position
Delay of 30 seconds