Sanyo PLC-XL51 Service Manual page 65

Sanyo multimedia projector service manual
Hide thumbs Also See for PLC-XL51:
Table of Contents

Advertisement

Item Name
Group/Item
11 OnStart Cooling Start Threshold
12 After shutdown cooling
Group 256
Fan Lamp Voltage Down Setting
0 Lamp Voltage
1 Lamp Vol Threshold
2 Fan1 Speed Gain
3 Fan2 Speed Gain
4 Fan3 Speed Gain
5 Not used
Group 257
Fan Dimmer Setting
0 Dimmer Average Check Period
1 Dimmer Average
2 Last Voltage Difference
3 Voltate Difference Goal
Group 258
Fan IC Temp for Netowrk model
0 Standby Cooling Check Cycle
Standby Cooling Start
1
Threshold
2 Standby Cooling Enable
Group 260
Auto Calibration (Commn)
0 Execute Calibration
1 Loop Count
2 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group 261
Auto Calibration (RGB)
0 OFFSET AREA H START
1 OFFSET AREA V START
2 GAIN AREA H START
3 GAIN AREA V START
4 Image AREA H WIDTH
5 Image AREA V HIGHT
6 OFFSET target
7 OFFSET torelance
8 GAIN target
9 GAIN torelance
Group 262
Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X
1 Y Image Area Start Y
6 Image Area H Width
7 Image Area V Hight
8 Y Target Level
11 Gain Tolerance
12 Delta Gain
Group 264
Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
2 CB - OFFSET AREA H START
3 CB - OFFSET AREA V START
Function
With Onstart on. At the time of
Power on after Cooling imperfect.
Cooling The temperature set point
for existence judgement
Cooling after shutdown (0: No, 1: Yes)
Current Lamp Voltage (0.1V)(Read
only)
Threshold to judge Lamp Voltage
Down ( V×10)
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:60sec, 3: 90sec
...10:300 sec)
Dimmer Avarage Value (Read only)
Read only (Unit : o.1V)
Read only (Unit : o.1V)
Temp B Check Cycle (Standby
mode) Unit : minute
Temp B start threshold (Standby
mode) Unit : minute
0 : Disable
1 : Enable
Maximum Execution Times (OFFSET-
>GAIN)
Result of Auto-Calibration (Last
Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start
Position
Black Level Acquiring Area V-Start
Position
White Level Acquiring Area H-Start
Position
White Level Acquiring Area V-Start
Position
Black/White Level Acquiring Area
Black/White Level Acquiring Area
Height
Target Value of Black Level Adj.
Torelance of Black Level Adj.
Target Value of White Level Adj.
Torelance of White Level Adj.
Y Acquiring Area H-Start Position
Y Acquiring Area V-Start Position
Image Level Acquiring Area
Image Level Acquiring Area Height
Target Value of Y Level Adj.
Torelance of Level Adj.
Deviation Width of Gain Value
Y - Offset Acquiring Area H-Start
Position
Y - Offset Acquiring Area V-Start
Position
CB - Offset Acquiring Area H-Start
Position
CB - Offset Acquiring Area V-Start
Position
- 65 -
Initial
Range Note
38
0-100
1
0-1
-
0-255
0
0-0
10
0-255
10
0-255
10
0-255
-
1
0-10
-
-
3
0-100
44
0-100
1
0-1
Executes Auto-Calibration when
0
0 - 1
changiing the Value (PC White 100%)
10
1 - 30
0
0 / 1 / 9
0: OK, 1: Adjusting,9: Error * ReadOnly
1
1 - 20
2
1 - 255
975
0 - 1000
500
0 - 1000
25
0 - 1000
500
0 - 1000
13
0 - 4095
9
0 - 4095
3
0 - 127
1
1 - 127
238
0 - 255
1
1 - 255
20
0 - 1000
200
0 - 1000
8
0 - 4095
9
0 - 4095
217
0 - 255
1
0 - 255
9
0 - 255
925
0 - 1000
500
0 - 1000
925
0 - 1000 If not used: use Y's value
500
0 - 1000 If not used: use Y's value
Service Adjustment

Advertisement

Table of Contents
loading

Table of Contents