Service Adjustment
Item Name
Group/Item
Group 254
Fan Control Range Setting (Temp./Voltage)
0 Not used
1 Not used
2 Not used
3 Not used
4 Not used
5 Not used
6 Not used
7 Not used
8 Not used
9 Not used
10 Normal Fan Control Min Temp
11 Normal Fan Control Max Temp
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
18 Not used
19 Not used
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
28 Not used
29 Not used
30 Filter Error Detect Temp
31 Filter Error Offset Volt
Group 255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
3 Not used
4 Fan1 Cooling Speed
5 Fan2 Cooling Speed
6 Fan3 Cooling Speed
8 Cooling Time L1
9 Cooling Time L2
10 Temp Error Cooling Time
Function
Temp Sensor Control Start/End Temp.
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Sensor Control Start/End Temp.
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Control Start Temp. (Temp B-A)
(Clogging Det.)
Fan Control Voltage Up
(Cloggiing Det.) (unit : 0.1V)
Fan Start Voltage (0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time setting at Fan Mode L1
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
- 64 -
Initial
Normal
Ceiling
Down
Up
27
27
27
27
20
20
20
20
36
36
36
36
30
30
30
30
85
85
85
85
105
105
105
105
135
135
135
135
135
135
135
135
98
98
98
98
110
110
110
110
130
130
130
130
130
130
130
130
85
85
85
85
110
110
110
110
100
100
100
100
130
130
130
130
9999
9999
9999
9999
9999
9999
9999
9999
27
27
27
27
20
20
20
20
36
36
36
36
30
30
30
30
75
75
75
75
75
75
75
75
130
130
130
130
135
135
135
135
82
82
82
82
82
82
82
82
110
110
110
110
110
110
110
110
60
60
60
60
75
75
75
75
68
68
68
68
125
125
125
125
9999
9999
9999
9999
9999
9999
9999
9999
17
17
17
17
18
18
18
18
10
10
10
10
20
20
20
20
70
70
70
255
130
130
130
2
3
3
Range Note
Normal/Celling/Down/Up
20-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
20-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
-
-
Normal/Celling/Down/Up
20-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
20-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
-
-
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-255
HiLand : Normal/ Celling/Down/Up
0-255
0-255
0-255
-
0-255
0-255
0-255
1-15
1-15
1-15