Sanyo PLC-XL51 Service Manual page 63

Sanyo multimedia projector service manual
Hide thumbs Also See for PLC-XL51:
Table of Contents

Advertisement

Item Name
Group/Item
Group 250
FAN Cntorol
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
2 FAN2 MIN ADJUST (DAC)
3 FAN2 MAX ADJUST (DAC)
4 FAN3 MIN ADJUST (DAC)
5 FAN3 MAX ADJUST (DAC)
6 Not used
7 Not used
Group 251
Not used
Group 252
Fan Option
0 HI-LAND SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 Not used
7 Stand Mode
Fan Offset Voltage Update In-
8
terval
Group 253
Fan Tem Error Setting (Memorized)
0 Not used
1 Not used
2 Not used
3 Not used
4 Not used
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
15 Temp A Warning Offset (Temp)
16 Temp B Warning Offset (Temp)
17 Temp C Warning Offset (Temp)
18 Temp B-A Warning Offset (Temp)
19 Temp C-A Warning Offset (Temp)
20 Temp A Warning Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp C Warning Offset (Time)
23 Temp B-A Warning Offset (Time)
24 Temp C-A Warning Offset (Time)
25 Factory Mode
Function
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Off, 1: Hi-Land 2: Hi-Land max
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
Stand mode setting
0: Normal(Free) 1: Normal(Fixed)
2: Celling 3: Down 4: Up
filter clogged Fan Voltage Update
interval time ( sec.)
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco (Panel)
Temp. C to judge the Temp Error at
Eco (Lamp)
Temp. B-A to judge the Temp Error at
Eco (Clogging Det.)
Temp. C-A to judge the Temp Error at
Eco (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased X°C at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
For factor use
- 63 -
Initial
42
234
42
234
42
234
9999 (Dummy)
9999 (Dummy)
0
0
0
130
130
130
0
60
Normal
Ceiling
Down
Up
44
44
44
44
33
33
33
33
56
56
56
56
50
50
50
50
73
73
73
73
68
68
68
68
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
44
44
44
44
33
33
33
33
56
56
56
56
49
49
49
49
74
74
74
74
67
67
67
67
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
5
5
5
0
0
1
1
1
1
1
0
Service Adjustment
Range Note
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 2
0 (Read Only)
0 - 6
0 - 3
0 - 255
0 - 255
0 - 255
0 - 4
1 - 600
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
30-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up
Normal/Celling/Down/Up
0-100
HiLand : Normal/ Celling/Down/Up

Advertisement

Table of Contents
loading

Table of Contents