Copyright Information; Password Information; Error Responses - Extron electronics IPL M PDP-ES User Manual

Interface card ip link tools
Hide thumbs Also See for IPL M PDP-ES:
Table of Contents

Advertisement

im Vertrieb von
Communication and Control
= Set local date and time format (MM/DD/YY-HH:MM:SS)
X13
(e.g., 11/18/04-10:54:00)
Read local date and time format (day of week, date month year
HH:MM:SS) (e.g., Thu, 18 Nov 2004 18:19:33)
= IP address (xxx.xxx.xxx.xxx) Leading zeros in each of four fields
X14
are optional in setting values, and are suppressed in returned
values.
= Mail Domain name (e.g., extron.com, icia.org)
X15
= Hardware (MAC) address (xx-xx-xx-xx-xx-xx)
X18
= Subnet mask (xxx.xxx.xxx.xxx); leading zeros in each of four
X19
fields are optional in setting values, and are suppressed in
returned values.
= Verbose/Response mode: 0 = clear/none; 1 = verbose mode;
X22
2=tagged responses for queries; 3 =v erbose mode and tagged
responses for queries. Default = 0 for Telnet connections.
If tagged responses are enabled, all read commands
return the constant string + the data, as setting the
value does. (e.g., Command: Esc CN
Ipn •x12
= Priority status for receive timeout: 0 = priority set to Send Data
X23
String command parameters; 1 = priority set to Configure rcv
timeout command parameters.
= Baud rate: 1200, 2400, 4800, 9600, 19200, 38400
X25
= Password: allows a maximum length of 12 characters.
X33
User password cannot be assigned if no administrator
password exists and returns E14. If an admin password
is cleared, then the user password is removed too.
= Daylight saving time: 0 = Off/ignore; 1 = U.S.; 2 =Europe;
X34
3 = Brazil.
Reading Password: If a password exists, it responds with 4
X41
asterisks (****). If no password exists, it appears empty.
= Email number: Range = 1-48 (max.)
X45
= Email recipient address
X46
= Name of email file to be sent. The first line of file is the subject;
X47
the rest is the body of the email.
Email files must have the file extension .eml.
www.camboard.de
4-20
IPL M PDP-ES • Communication and Control
Response:
).
CAMBOARD Electronics
Tel. 07131 911201
Fax 07131 911203
There is a 7 character limit for full file names. It is
advised that you use numeric titles (e.g., 1.eml, 24.eml).
Numeric titles reduce the characters of the file name, and
assist in keeping the alert files organized. However,
alphabetical titles are permitted.
= Default Name: combination of model-name and last 3 pairs of
X49
MAC address (e.g., IPL-M-PDP-ES 00-02-3D)
= Connection's security level: 00 = anonymous; 11 = user;
X52
12 = Administrator
= The number of seconds before timeout: (min = 1; max = 65535;
X69
default = 30 = 300 seconds). If no data is received during the
timeout period, the Ethernet connection is closed. Each step =
10 seconds. The response is returned with leading zeros.
Applicable to Ethernet only.
= Number (as optional parameter) inserted into an email message
X70
if .eml file has an embedded ESC CR command with no params.

Copyright information

© COPYRIGHT 2004, EXTRON ELECTRONICS IPL M
PDP-ES, Vx.xx
Thur, 18 Feb 2004 11:27:33
The copyright message is displayed upon connecting to IP
Link product via TCP/IP or Telnet. Mxx is the model and
Vx.xx is the firmware version number. The current date and
time are displayed. This is followed by a Password prompt.

Password information

The
Password: prompt requires a password (administrator
level or user level) followed by a carriage return. The prompt
is repeated if the correct password is not entered.
If the correct password is entered, the unit responds with
Login Administrator
or
password entered. If passwords are the same for both
administrator and user, the unit defaults to administrator
privileges.

Error responses

When the IPL T S interface receives a valid command, it
executes the command and sends a response to the host device.
If the unit is unable to execute the command because the
ce-info@camboard.de
IPL M PDP-ES • Communication and Control
Login User
, depending on
4-21

Advertisement

Table of Contents
loading

Table of Contents