Inspecting Burner; Pilot Flame Pattern; Burner Flame Pattern - Procom MD2TPA User Manual

Vent-free gas wall heater infrared
Table of Contents

Advertisement

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure 22 shows a incorrect pilot flame pattern. The incorrect pilot
flame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off. If
pilot flame pattern is incorrect:
• turn heater off (see "To Turn Off Gas to Appliance" on page 18)
• see Troubleshooting pages 21 through 23.
Figure 21 - Correct Pilot Flame Pattern
WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If
burner flame pattern shows yellow tipping, follow instructions at bottom of this page.
Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn
causing brief patches of orange flame.

BURNER FLAME PATTERN

Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If burner
flame pattern is incorrect then:
• turn heater off (see "To Turn Off Gas to Appliance" on page 18).
• see Troubleshooting, pages 21 through 23
Fig. 22 - Correct Pilot Flame Pattern with Control
Knob Set to High Flame (5)
Figure 22 - Incorrect Pilot Flame Pattern
Fig. 22 - Incorrect Pilot Flame Pattern with
Control Knob Set to High Flame (5)
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md3tpaMd5tpaMd3tpa-bbMd5tpa-bb

Table of Contents