(3) Back-up switch
When the remote controller become weak, or if the remote controller is lost or malfunctioning, this switch may be used to turn the
unit on and off.
(a) Operation
Push the switch once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Detail of operation
Operation starts in the same way as the previous operation.
Models SKM22, 25 models
(4) Flap control
Control the flap by AIRFLOW button on the wireless remote control.
(a) Natural flow (AUTO)
The flap will be automatically set to the angle of air flow best to operation.
1)
Starting time of operation
In case of cooling
s
and dry operation
Stops at the level position for
one minute.
¡ The flap operation as shown above will be repeated.
2)
When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b) Memory flap (Only case of SKM28, 32, 40 models)
While the flap is operating if the AIRFLOW button is pushed once, it stops swinging at an angle.
As this angle is memorized in the microcomputer, the flap will be automatically set to the angle when next operation is
started.
Recommendable stopping angle of the flap
COOL•DRY
(c) Swing flap
Flap moves in upward and downward directions continuously.
206
ON/OFF button
t
Sway operation
Horizontal
blowing
Models SKM28, 32, 40 models
ON/OFF
In case of heating
s
t
operation
Sway operation
¡ The flap operation as shown above will be repeated.
HEAT
ON/OFF button
Slant forward
blowing