Electrical Data; Electrical Wiring - Mitsubishi SCM45ZA User Manual

Inverter multi-split system room air-conditioner
Table of Contents

Advertisement

6.3

ELECTRICAL DATA

Meaning of marks
• Outdoor Unit
Symbol
CM
Compressor motor
FM
Fan motor
0
L
Reactor
DS
Diode stack
EEVA, B
Electric expansion valve
20S
4 way valve (coil)
• Indoor Unit
Symbol
FM
Fan motor
I
CF
Capacitor (for FM
I
SM
Flap motor
TR
Transformer
ZNR
Varistor

6.3.1 Electrical wiring

(1) Indoor unit
Models SKM22ZA, 25ZA, 28ZA, 32ZA, 40ZA
BL
GR
PP
FM
I
Y
WH
RD
SM
Parts name
Parts name
)
I
TR
RD RD
BK BK
CNW
CNC
CNB
CF
I
CF
COM
FM
I
CNU
Q
Printed circuit board
CNM
CNE
Display
Symbol
Tho-A
Thermistor (outdoor air temp.)
Tho-R
Thermistor (outdoor H.X temp.)
Tho-D
Thermistor (comp. dome temp.)
LED2
Warning lamp (Red)
LED1, 3
Serial signal lamp (Green)
Symbol
Q
Fan motor control triac
F
Fuse
Th
-A
Thermistor (Room temp.)
I
Th
-R
Thermistor (Indoor H. X temp.)
I
RD
WH
BK
R
J
S
F (250V · 3.15A)
ZNR
CND
CNG
Back up
switch
Th
A Th
Wireless
I-
R-Amp
Parts name
Parts name
3
2
Power line
1
(Outdoor unit)
Y/GN
Color symbol
BK
Black
BL
Blue
GR
Gray
Y
Yellow
RD
Red
WH
White
PP
Purple
Y/GN
Yellow/Green
R
I-
203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Skm25zaSkm28zaSkm22zaSkm32zaSkm40za

Table of Contents