Periodical Checks; Considerations Before A Long Shutdown Period Of Air Conditioner - Carrier Harmony 53VMCT 18C-24C-30C-36C Owner's Manual

Floor / under ceiling split air conditioners
Table of Contents

Advertisement

10. PERIODICAL CHECKS

WARNING:
It is necessary to stop the air conditioner and disconnect the power supply before
performing service and maintenance operations.
For a good operation of the air conditioner it is recommended to carry out periodic service and
maintenance of the air conditioner or upon customer request through Carrier or Carrier authorized dealer.
Recommended service and maintenance works and intervals may vary depending on the installation
environment, e.g. dusty zones, etc. see below table :
Indoor Unit
(3)
Clean air filters
(2)
Clean drain pipe
Change remote control batteries
Outdoor Unit
Clean outdoor coil
Blow air over electric parts
Check electric connection tightening
(2)
Clean fan wheel
Check fan tightening
(2)
Clean drain pan
NOTES
(1) Increase frequency in dusty zones.
(2) Service and maintenance works to be carried out by qualified service personnel.
(3) Cleaning air filters can be done by customer every month.
(4) Changing batteries of remote control can be done by customer every year.
11. CONSIDERATIONS BEFORE A LONG SHUTDOWN
PERIOD OF AIR CONDITIONER
Keep the indoor unit in operation for half
a day in the ventilation (fan only) mode
in order to dry all internal parts.
Switch electric mains supply off.
Take batteries out of the remote control.
Clean indoor and outdoor units.
Clean the air filters and reposition them
in the unit.
(4)
(2)
(2)
(2)
(2)
Every Month
Every Month
12h
( 24 )
Every Year
(1)
Every Year

Advertisement

Table of Contents
loading

This manual is also suitable for:

Harmony 53vmct 18h-24h-30h-36h

Table of Contents