Download Print this page
Medela 67355S Instructions Manual
Medela 67355S Instructions Manual

Medela 67355S Instructions Manual

Double duet breastmilk initiation kit

Advertisement

Quick Links

double duet
breastmilk
initiation kit
instructions
for use with symphony breastpump
includes harmony manual breastpump
double or single pumping kit
24 mm and 27 mm PersonalFit
DEHP and Latex free
breastshields
67355S

Advertisement

loading
Need help?

Need help?

Do you have a question about the 67355S and is the answer not in the manual?

Questions and answers

Summary of Contents for Medela 67355S

  • Page 1 24 mm and 27 mm PersonalFit breastshields ™ DEHP and Latex free 67355S...
  • Page 2: Table Of Contents

    Double Duet Breastmilk Initiation Kit To purchase non-sterile replacement parts: • Locate a Medela retailer at http://medela.findlocation.com • Email customer.service@medela.com, or • Call 1-800-435-8316 24 mm PersonalFit ™ Breastshield (2) 87073 Let-down Symbol Handle (1) 8007262 Diaphragm (1) Stem w/...
  • Page 3 Medela’s 80 mL breastmilk collection container has 65 mL of pumping capacity and 80 mL of storage capacity. Visit your Medela retailer or go to www.medela.com for our selection of larger breastmilk collection & storage containers.
  • Page 4: Breastshield

    Pumping Should Be Comfortable When it comes to finding the right fit in a breastshield every 24 mm mother is different. Sizing may change throughout your breastfeeding experience as the breast and nipple tissue changes. To determine the 27 mm correct size breastshield, you need to watch your breasts while pumping.
  • Page 5 If you experience discomfort while pumping, contact your lactation professional as you may need a different size breastshield. To locate Medela products, visit http://medela.findlocation.com or call 1-800-TELL-YOU. Single User Caution: This product is a personal care item that should not be shared between users.
  • Page 6 Symphony Pumping Kit Assembly & Use ® 1 Securely attach breastshields to connectors. (Note: See inside cover for selecting Wash hands with soap and water the proper size prior to handling your kit. breastshield.) 2 Snap white 3 Push yellow valves 4 Screw collection membranes onto inner ring of...
  • Page 7: Handle

    8 To open lid, hold 9 Push membrane 10 Close lid before down the oval caps into place on pumping. button on the top of the pump. A “click” (If lid does not the Symphony will be heard once close, check to see breastpump and properly seated.
  • Page 8: Diaphragm

    Harmony Kit Assembly & Use ™ 1 Securely attach 2 Snap white breastshield to membrane onto connector. yellow valve until membrane lie flat. Wash hands with soap and water prior to handling your kit. 3 Push yellow valve 4 Screw collection 5 Place oval shaped onto inner ring of container onto...
  • Page 9 7 Insert stem of 8 Center breastshield handle assembly over nipple. into opening on top (Caution: pushing of connector and shield too firmly into push until you feel breast may reduce it snap in. milk flow.) 9 Rotate the 10 Start pumping in 11 Once let-down adjustable handle has begun, switch...
  • Page 10 Converting to the Symphony Breastpump ® 1 Remove handle assembly from connector. 2 Insert pale yellow round end of tubing into opening on top of connector. See Symphony Kit Assembly on page 2 and refer to steps 6-14 to complete assembly. Breastpump Kit Care Good hygiene will help protect the breastmilk that you give to your baby.
  • Page 11 How do I disassemble my kit? 1 Finish pumping. Symphony: While the pump is still (Note: It is important to let pump running, disconnect run for 2 minutes with tubing tubing from connector. attached. This will eliminate condensation that naturally results from humidity.) Both Symphony and Harmony: 2 Remove collection container(s) and store breastmilk.
  • Page 12: Yellow Valve

    How do I disassemble my kit? (cont’d.) Both Symphony and Harmony ® ™ Separate remaining parts of your kit that come in contact with your breast and breastmilk. b Separate breastshield(s) c Twist and pull the from connector(s). yellow valve(s) off the connector(s).
  • Page 13 Do NOT store wet or damp parts. Sanitizing In addition to washing, you may sanitize your kit parts that come in contact with breast and breastmilk once per day by following the instructions on Medela’s Quick Clean Micro-Steam bag or boiling. ™...
  • Page 14: Tubing Care

    If soreness persists, contact a lactation consultant or healthcare provider to assist in proper breastshield sizing or comfortable breastfeeding techniques. • To soothe sore nipples, you may purchase Tender Care products by visiting your Medela retailer. To locate a retailer visit www.medela.com or call 1-880-TELL YOU.
  • Page 15: Troubleshooting

    (Refer to step 6 of the Harmony Kit Assembly Instructions on page 4.) If assistance is still needed after reviewing this booklet, please email Medela Customer Service at customer.service@medela.com or call (800) 435-8316 or (815) 363-1166.
  • Page 16 Medela, Symphony y Lactina son marcas registradas de Medela en EE.UU. PersonalFit, Quick Clean y Micro-steam son marcas comerciales de Medela, Inc. en EE. UU. y en otros países. Solicitudes de registro de Medela en trámite en otros países. © 2011 Medela, Inc. Impreso en los EE.UU.