Technical information

Model IVT Optima
Emitted/Supplied output at +7/35º
Emitted/Supplied output at +7/45º
Heat carrier fl ow nominal
Internal pressure drop heat carrier
Air fl ow
Electrical consumption fan
Electrical supply
Fuse size
Compressor
Highest outgoing heat carrier temperature
Refrigerant fi lling R-407C
HTF connection
Defrost system
Dimensions (WxDxH)
1)
Weight
Colour
Outer casing
Output data at +7/35º and +7/45º are stated according to the European standard EN 14511.
1)
Dimensions excl. feet, supplied min 20 mm - max 30 mm depending on adjustment
Control cabinet and accessor y unit electric/oil-fi red boiler
Dimensions
Control cabinet (WxDxH)
Accessory unit (WxDxH)
600
900
kW
5.5 / 1.4
7.2 / 2.0
kW
5.1 / 1.7
7.0 / 2.4
l/s
0.19
0.29
kPa
5
6
m³/h
2200
2200
A
0.44
0.44
AT
10
ºC
kg
2,5
2,6
mm
Hose 1 inch internal thread
mm
820x640x1190
kg
140
145
mm
335x112x296
mm
255x100x180
43
1100
1400
8.9 / 2.3
12.9 / 3.3
8.6 / 2.8
12.5 / 4.0
0.34
0.47
7
7
2200
5500
0.44
0.7 (400V N3)
400V 3N~ 50Hz
Scroll
65
2,7
3,4
external G25
Hot gas with four-way valve
920x705x1660
155
160
Champagne
Galvanised enamelled plate
Technical information
1700
14.3 / 3.9
14.1 / 4.7
0.55
8
5500
0.7 (400V N3)
16
3,5
165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optima 600Optima 900Optima 1100Optima 1400Optima 1700