SCM-C
7.2

SELECTION DATA

7.2.1 Specifications

(1) Indoor Unit
Models SKM258CENF-L, 328CENF-L
Item
Cooling capacity
Power source
Noise level
(4)
Exterior dimensions
Height × Width × Depth
Color
Net weight
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at high)
Air filter, Q'ty
Operation switch
Room temperature control
Pilot lamp
O.D
Connecting method
Refrigerant
piping
Attached length piping
Insulation
Drain hose
Size × Core number
Connection
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
(2) The operation data indicate when the air conditioner is operated at 220V and 240V (SKM258CERF·220V) respectively.
(3) Limitation of Voltage application
Minimum: 198V
(4) Expressed in sound pressure level.
236
Model
W
dB (A)
mm
kg
W
CMM
mm (in)
Item
Indoor air temperature
DB
27ºC
Maximum: 264V
SKM258CENF-L
2200/2200
1 Phase, 220/240V, 50Hz
38/39
275 × 790 × 174
Ivory white
7.5
Tangential fan × 1
16
7.5 / 7.5
Polypropylene net (washable) × 2
Wireless-Remote controller
MC, Thermostat
RUN (Green), TIMER (Yellow)
Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")
Flare connecting
Liquid line: 0.4 m Gas line: 0.35 m
Necessary (Both sides)
Connectable
× 4 cores (with Earth)
1.5 mm
2
Terminal block (screw fixing type)
Mounting kit
Outdoor air temperature
WB
DB
19ºC
35ºC
SKM328CENF-L
2600/2600
40/42
8
9/9
Standards
WB
24ºC
JIS C9612, ISO-T1