Model SRK28HD (Indoor unit)
SRC28HD (Outdoor unit)
Item
(1)
Cooling capacity
Heating capacity
(1)
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP
Cooling
Noise level
Heating
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(3)
Refrigerant
Refrigerant oil
Deice control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Size × Core number
Connection wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
If the piping length is longer, when it is less than 10 m, add 20 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.
Model
W
W
kW
A
kW
A
A
sound level
Power level
dB
sound level
Power level
mm
kg
kW
kg
R
W
(Cooling)
CMM
(Heating)
Frost protection, Serial signal error protection
Fan motor error protection
mm (in)
Item
Indoor air temperature
DB
27ºC
20ºC
SRK28HD
1 Phase, 220/230/240V, 50Hz
(55)
(56)
250 × 815 × 249
Cool white
9.0
Louver fins & inner grooved tubing
Capillary tubes
R22 0.8 (Pre-Charged up to the piping length of 7.5m)
0.35 (SUNISO 4GDID or ATMOS M60)
Tangential fan × 1
14
8.0
8.5
Polypropylene net (washable) × 2
Wireless-Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")
Flare connecting
Liquid line: 0.4 m
Gas line : 0.33 m
Necessary (Both sides)
2.5 m (3 cores with Earth)
× 4 cores (Including earth cable)
2
1.5 mm
Terminal block (Screw fixing type)
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
2
-
-
SRC28HD
(60)
(60)
540 × 720 × 290
Stucco white
32
2PS164D5BF02 (Rotary type) × 1
0.75
Line starting
MC control
Propeller fan × 1
15
30
30
Cushion rubber (for compressor)
Compressor overheat protection, Overcurrent pro-
tection, Serial signal error protection
Connectable
Mounting kit
WB
24ºC
6ºC
Standards
ISO-T1, JIS C9612
ISO-T1, JIS C9612