Selection Data; Specifications - Mitsubishi Heavy Industries SRK10CFV-4 Technical Manual & Parts List

Room air-conditioning wall mounted type room air-conditioner (split system, air cooled cooling only type)
Table of Contents

Advertisement

2

SELECTION DATA

2.1 Specifications

Model
SRK10CFV-4 (Indoor unit)
SRC10CFV-4 (Outdoor unit)
Item
Cooling capacity
(1)
Power source
Cooling input
Running current (Cooling)
Inrush current
COP (In cooling)
(4)
Noise level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor types & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(3)
Refrigerant oil
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Size × Core number
Connection
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
(2) The operation data are applied to the 220 V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7.5 to 15 m, add 10 g refrigerant per meter.
(4) Expressed in sound pressure level.
All manuals and user guides at all-guides.com
Model
SRK10CFV-4
BTU
kW
A
A
dB
268 × 790 × 199
mm
kg
kW
Louver fins & inner grooved tubing
kg
R22 0.9 (Pre-Charged up to the piping length of 7.5m)
R
Tangential fan × 1
W
CMM
Polypropylene net (washable) × 2
Wireless-Remote control
Microcomputer thermostat
RUN (Green), TIMER (Yellow),
HI POWER (Green), 3D AUTO (Green)
Frost protection,
Fan motor error protection
mm (in)
Liquid line: 0.4 m
Gas line : 0.33 m
Indoor air temperature
DB
WB
27°C
19°C
3
-
-
9000
1 Phase, 220V, 50Hz
0.73
3.4
18
3.62
39
Fine snow
8.5
Louver fins & inner grooved tubing
Capillary tubes
0.35 (SUNISO 4GSI or ATMOS NM56)
16
9.0
Cushion rubber (for compressor)
Internal thermostat (for compressor)
Liquid line: ø6.35 (1/4") Gas line: ø9.52 (3/8")
Flare connecting
Necessary (Both sides)
Connectable
2.5 m (3 cores with Earth)
× 3 cores (Including earth cable)
2
1.5 mm
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
DB
35°C
24°C
(220V)
SRC10CFV-4
45
540 × 780 × 290
Stucco white
30
RSA201A018
0.69
Line starting
Propeller fan × 1
14
26.5
Standards
WB
ISO-T1, JIS C9612

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk13cfv-4Src10cfv-4Src13cfv-4

Table of Contents