Ac-I N Cabling; Table 3, Recommended Minimum Ac Wire Sizes - Trace Engineering Mariner Owner's Manual

Inverter/charger
Hide thumbs Also See for Mariner:
Table of Contents

Advertisement

4 8 , & . , 1 6 7 $ / /
$&,Q &DEOLQJ
Disconnect all AC sources before beginning. This includes shorepower, inverter, or generator.
Disable generator autostart feature if vessel is so equipped. Use the appropriate size AC cabling as
determined by the following table:
,
Table 3
Recommended Minimum AC Wire Sizes
Inverter Model
&DXWLRQ
This inverter/charger includes neutral-to-ground switching for the AC electrical
system. In marine installations, the AC neutral must be physically isolated from
the ground throughout the load distribution that is powered by the inverter.
Remove the knockout from the front or either side of the inverter chassis and install a strain relief
or conduit in which to route the AC cabling in and out.
Connect the black wire from an appropriately sized three-conductor AC cable from the hot side
of the AC source selector switch and/or disconnect device to the terminal labeled "AC Input Hot
1" on the inverter. Never connect both shorepower and generator power to the inverter at the
same time. ABYC standards require a disconnect switch within 10 feet of the shore power inlet
connector.
Connect the white wire from the neutral side of the AC source to the terminal labeled "AC Input
Neutral" on the inverter.
Connect the green wire from the ground of the AC source to one of the two green wires (AC
Safety Ground) bolted to the chassis of the inverter/charger.
8‚ƒ’…vtu‡Ã‹ÃU…hprÃ@tvrr…vtÃ8‚ÃDp
WK
$( %Ã ($
ÃT‡…rr‡ÃI@
6…yvt‡‚ÃX6ÃÃ('!!"ÃVT6Ã
120 VAC Input
M2012
10 AWG
M2512
8 AWG
M3012
8 AWG
Uryrƒu‚rÃ"%Ã#"$''!%
Ah‘Ã"%Ã#"$!!!(
‡…hprrtvrr…vtp‚€
120 VAC Output
12 AWG
10 AWG
10 AWG
Qh…‡ÃIˆ€ir…Ã"$%
Pp‡‚ir…Ã!&à (('

QhtrÃ

Advertisement

Table of Contents
loading

Table of Contents