Service Flow Chart - Hisense AS-09UR4SVNVG1 Service Manual

Split type
Table of Contents

Advertisement

7
T
R
O
U
B
7
T
R
O
U
B

7-2. Service flow chart

Switch on the power
supply
Does
DLED
screen
display normally?
No
Is
the
fuse(F01,
3.15A/250V) blown?
No
Are the wires poorly
connected?
No
Check
the
first
and
secondary
voltage.
The first voltage:220V
The secondary voltage:
*C15:12V
CN4(1,2terminal):5V
No
After
replacing
the
display board, Is there
still trouble?
No
Indoor control board is faulty.
Replace it.
L
E
S
H
O
O
T
I
N
G
L
E
S
H
O
O
T
I
N
G
Yes
Yes
Yes
Check all wires are
connected correctly
Replace
Yes
the
control
board
Yes
Display
board
trouble
Does it receive the
Yes
remote
controller
signal?
No
Is
the
remote
controller in good
condition
Yes
After
replacing
the
display
board.
Yes
Replace
the
indoor board.
Is
there
still
trouble?
Yes
Is indoor control
board
short
circuit?
Yes
Replace
the
indoor
Start up self-test
function
Check the result
No
Replace the battery press
ACL button.
Retry remote operation.
No
Display
board
problem
No
Check operation
Check
and
find
short circuit or open
No
circuit among other
components
such
as transformer or
fan motor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-12ur4svgvgAs-18ur4stvvgAs-12ur4svnvg1As-24ur4sqjvg

Table of Contents