Download Print this page

Troubleshooting; Specifications - GE 62191 Installation Manual

Ge led wall washer led lighting system

Advertisement

Troubleshooting

Symptom
All LED fixtures are not
illuminated
Some LED fixtures are
not illuminated
Shadows within
application

Specifications

Product Code Description Code
62199
(LWW1-HO12-012-827)
62202
(LWW1-HO12-030-827)
62191
(LWW1-HO12-110-827)
65444
(LWW1-HO12-012-830)
65445
(LWW1-HO12-030-830)
62192
(LWW1-HO12-110-830)
62200
(LWW1-HO12-012-840)
62203
(LWW1-HO12-030-840)
62195
(LWW1-HO12-110-840)
62204
(LWW1-MO12-012-827)
62206
(LWW1-MO12-030-827)
62196
(LWW1-MO12-110-827)
65446
(LWW1-MO12-012-830)
65447
(LWW1-MO12-030-830)
65448
(LWW1-MO12-110-830)
62205
(LWW1-MO12-012-840)
62207
(LWW1-MO12-030-840)
65449
(LWW1-MO12-110-840)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harm-
ful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This
Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme á la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
GE Lighting • 1-888-MY-GE-LED
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company.
© 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Solution
• Check leader cable connection and/or check circuit breaker.
• Check plug connectors on the LED fixtures for improper connections or short circuits.
• Ensure leader cable is securely connected to the female plug connector on the first LED fixture.
• Check plug connectors on the LED fixtures for improper connections or short circuits.
• Ensure any jumper cables are securely connected between the male/female plug connectors of the
LED fixtures.
• Re-position LED fixtures along mounting surface ensuring architectural elements are not directly in
front of any LEDs.
• Adjust layout of LED fixtures to ensure uniformity of illumination.
• Adjust leader cable and/or jumper cable orientation to ensure cables do not cover any LEDs.
Voltage
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
120 VAC-277 VAC, 50-60Hz
IP Rating
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
IP51: Dry or Damp Location
• www.gelighting.com
(1- 8 8 8 - 6 9 - 4 3 - 5 33 )
Maximum Run Length
For 120 VAC: 70 Fixtures
(~73.5 feet/22.41m)
For 240 VAC: 140 Fixtures
(~147 feet/44.82m)
For 277 VAC: 165 Fixtures
(~173.3 feet/52.84m)
For 120 VAC: 140 Fixtures
(~147 feet/44.82m)
For 240 VAC: 290 Fixtures
(~304.5 feet/92.84m)
For 277 VAC: 300 Fixtures
(~315 feet/96.04m)
ARCH053-100213

Advertisement

loading

This manual is also suitable for: