Total Time Of Ascent; Decompression Obligation - Uwatec Aladin 2G User Manual

Dive computer
Table of Contents

Advertisement

The attention message "Level stop ignored"
is activated if the requested level stop is not
observed. An attention beep* goes off and the
arrow
, the depth and duration of the
STOP
ignored level stop begin flashing.
To complete the dive without being reduced
to a lower MB level, you must descend to the
prescribed depth immediately!
MB level reduced
DEPTH
STOP
New MB level
The warning "MB level reduced" is activated if
the diver ascends more than 1.5m (5ft) above
the required level stop. Aladin 2G reduces the
MB level, an attention beep* goes off and the
new MB level is shown in the lower left corner.
To complete the dive without being further
reduced to an even lower MB level the new
level stop must be observed.
)
NOTE:
* Attention beeps can be suppressed
with "set 1" (->61) or via SmartTRAK.
SCUBAPRO ALADIN 2G
WARNING
4s
DIVE TIME
CNS O
%
2
WARNING
6. Diving with microbubble (MB) levels

6.4.2 Total time of ascent

DEPTH
DIVE TIME
NO
STOP
CNS O
Total ascent time
Aladin 2G displays the level stop information
and the total time of ascent. This includes
the time of ascent as well as all level stops.
)
NOTE:
The total time of ascent is calculated
on the basis of the prescribed ascent
rate. Total time of ascent can be subject
to change if the ascent rate is not ideal
(100%).

6.4.3 Decompression obligation

Aladin 2G calculates and displays level
stops to reduce microbubble formation, but
it also calculates the diver's decompression
data.
WARNING
Avoid decompression dives when diving with
MB levels.
4s
DEPTH
DIVE TIME
DECO
STOP
CNS O
How to avoid decompression stops:
• Check ordinary no-stop time by pushing
until L0 appears.
%