Visual inspection of fl ame through sight glass. Burner
should be fully illuminated. See fi gure 9-5.
•
Check expansion tank.
11.2 Annual shut down procedure
•
Follow instructions "To Turn Off Gas To Appliance"
boiler is also used to supply domestic hot water. See
section 10.
•
Drain system completely and add antifreeze when
heating system is to remain out of service during freezing
weather.
•
Drain condensate lines when boiler is to be exposed to
freezing temperatures.
WARNING
!
Following service procedures must be performed
by qualifi ed service agent. Boiler owner shall not
attempt these steps.
WARNING
!
Use gloves when handling refractory to avoid
absorption of crystiline silica a potentially dangerous
compound.
11.3 Annual Examination and Cleaning of Boiler
Components
•
Obtain Burner Inspection Kit. See "Parts, Kits and
Optional Accessories" manual.
•
Before servicing, turn off electrical power to boiler at
service switch.
•
Follow instruction 'To Turn Off Gas to Appliance'. Close
main gas valve.
•
Visually inspect through sight glass verify no fl ame is
present.