Heating Element

The heating element can be activated using TEST
Mode.
The dual-wattage heating element produces 850
watts during wash, to help heat the water, and an
effective wattage due to cycling of 541 watts during
the dry cycle.
Water inlet temperature must be at least 120 °F for
proper drying. Lower water inlet temperature will
prevent proper convection air movement and
increase drying time substantially.
If the problem is that the dishes are not drying
correctly, don't overlook the rinse agent. A rinse
agent will improve the water sheeting action and
drying performance.
It is normal for the stainless steel tub and inner door
panel to retain water droplets even though the dishes
are dry.
Heating element Strip Circuit
The heating element nuts are located on the
underside of the washer, near the door. Ample force
is required to remove the nuts. Removing the
dishwasher from installation may be required.
 
 
Test Mode
In standby mode, push HI-TEMP, HEATED-DRY and
HI-TEMP WASH, the machine will enter into the process of
Test Mode. After entering the self inspection mode, all
lights will be ON and the display will show 88, then operate
the unit according to the following order:
Touch the POTS & PANS the inlet water valve will
work for 90 seconds
Touch the NORMAL, the wash pump will work for 2
minutes and stop for 1 minutes, then repeat.
Touch the CHINA pad, the detergent dispenser will
work for 1 minute and stop for 2 minutes, then
repeat.
Touch the Speed pad, the heating element and wash
pump will work simultaneously for 1 minute and stop
for 1 minute, then repeat.
Touch the RINSE&HOLD pad, the heating element will
work for 5 minutes and stop for 5 minutes, then
repeat
Touch the SANITIZE RINSE pad, the drain pump will
work for 2 minutes and stop for 1 minute, then
repeat.
Touch the HI-TEMP pad, the wax motor will work for
1 minute and stop for 1 minute, then repeat.

Turbidity Sensor

The turbidity sensor is located in the front of sump.