Download Print this page

Maintenance; Specifications/5650F Classifications - DeVilbiss Pulmo-Aide 5650C Instruction Manual

Compressor/nebulizer
Hide thumbs Also See for Pulmo-Aide 5650C:

Advertisement

Maintenance

All maintenance must be performed by a qualified DeVilbiss provider or authorized service center.
DaNgER
Electric shock hazard. Do not remove compressor cabinet. All disassembly and maintenance must be done by a
qualified DeVilbiss provider.
SpECiFiCaTioNS/ClaSSiFiCaTioNS
Size .......................................................................................................... 10.1" D x 10.5" H x 6.5" W (26 cm x 27 cm x 17 cm)
Weight ................................................................................................................................................................7.1 lbs. (3.2 kg)
Electrical Requirements:
5650D & 5650C ..............................................................................................................................1.3 amps, 115VAC 60Hz
5650I .............................................................................................................................................. 0.8 amps, 230VAC 50Hz
5650K & 5650P ......................................................................................................................... 0.8 amps, 230VAC 50/60Hz
5650F ............................................................................................................................................. 0.8 amps, 230VAC 50Hz
Sound Level:
All Models except 5650F ....................................................................................................................................... 51-55 dBA
5650F .................................................................................................................................................................... 49-53 dBA
Power Consumption:
5650D & 5650C .......................................................................................................................................90 watts maximum
5650I, 5650K & 5650P ...........................................................................................................................100 watts maximum
5650F .....................................................................................................................................................105 watts maximum
Maximum Compressor Pressure ................................................................................................................... 30 psig (206 kPa)*
Compressor Free Air Flow 5650 .....................................................................................................................................12 lpm*
Operating Temperature Range:
All Models except 5650C .......................................................................................................+40° to +104°F (+5 to +40°C)
5650C ..................................................................................................................................+40° to +101°F (+5 to +38.5°C)
Operating Humidity ...........................................................................................................................up to 95% non-condensing
Storage/Transport Temperature Range .....................................................................................-40° to +140°F (-40° to +60°C)
Storage/Transport Humidity .............................................................................................................up to 95% non-condensing
Storage/Transport Pressure ..................................................................................................... 7.3 to 15.4 psia (50 to 106 kPa)
Supplied Nebulizer Capacity .......................................................................................................................................10 ml (cc)
Supplied Nebulizer Nebulization Rate .................................................................................................... 0.15 ml/min or greater*
Supplied Nebulizer MMAD ............................................................................................................................5 microns or less**
*Conditions may vary based on altitude above sea level, barometric pressure, and temperature.
**Value determined with minimum flow rate through the nebulizer (20°C, sea level).
5650F Classifications
With respect to protection against electric shock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class II
Degree of protection against electrical shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BF Applied Parts
Degree of protection against ingress of liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IPXO
Mode of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous