Dimplex System 18 Installation And Servicing Instructions page 9

System condensing boilers
Table of Contents

Advertisement

4 4 . . 0 0
T T E E C C H H N N I I C C A A L L D D A A T T A A
4 4 . . 1 1
P P E E R R F F O O R R M M A A N N C C E E D D A A T T A A
A A p p p p l l i i a a n n c c e e C C l l a a s s s s i i f f i i c c a a t t i i o o n n C C 1 1 3 3 , , C C 3 3 3 3 , , C C 5 5 3 3 , , B B 2 2 3 3
Mode
Output (non-condensing)(80-60°C)
Output (condensing)(50-30°C)
Input Max Rate
Input Min Rate
Gas Rate (after 10 min operation - hot)
Seasonal Efficiency
Seasonal Efficiency (SEDBUK)
Nox Classification
Min System Pressure
Max System Pressure
Max Central Heating Flow Temperature
Min Central Heating Flow Temperature
G G e e n n e e r r a a l l S S p p e e c c i i f f i i c c a a t t i i o o n n s s
Max lift weight
Total water capacity
Integral expansion vessel capacity
Maximum heating system water content using fitted expansion vessel, @ 0.75 bar
Electrical supply
Internal fuse
Maximum power consumption
IP Rating
Flue gas temperature 80/60
Flue gas temperature 50/30
CO
value max rate (Nat Gas) (Case must be fitted when taking reading)
2
CO
value min rate (Nat Gas) (Case must be fitted when taking reading)
2
CO value max rate (Nat Gas) (Case must be fitted when taking reading)
CO value min rate (Nat Gas) (Case must be fitted when taking reading)
CO
value max rate (Propane) (Case must be fitted when taking reading)
2
CO
value min rate (Propane) (Case must be fitted when taking reading)
2
CO value max rate (Propane) (Case must be fitted when taking reading)
CO value min rate (Propane) (Case must be fitted when taking reading)
Gas Pressure - Natural Gas
Gas Pressure - Propane
C C o o n n n n e e c c t t i i o o n n s s
Gas
CH flow
CH return
Pressure relief valve outlet
Condensate Drain
P P . . P P . . M M = = P P a a r r t t s s P P e e r r M M i i l l l l i i o o n n
S S y y s s t t e e m m 1 1 8 8
Rate
Max
kW
18.1
Min
kW
6.0
Max
kW
19.7
Net
kW
18.4
Gross
kW
20.4
Net
kW
5.4
Gross
kW
6.0
3
Max
m
/h
1.95
%
90.3
Band
"A"
Class
"5"
Bar
0.5
Bar
2.5
°C
80
°C
30
kg
33.6
Ltr
1.8
Ltr
8
Ltr
84
240V 50Hz Fuse at 3A
T4H 4A 250V
W
100
IPX4
°C
59
°C
41
%
8.8-9.2
%
8.5-8.9
P.P.M
15-60
P.P.M
0-40
%
10.8-11.2
%
10.4-10.8
P.P.M
80-160
P.P.M
0-40
mbar
18-20
mbar
37
22 mm compression
22 mm compression
22 mm compression
15 mm compression
21.5 - 22 mm plastic overflow pipe
S S y y s s t t e e m m 3 3 0 0
29.8
8.1
32.5
30.4
33.7
7.6
8.4
3.2
90.3
"A"
"5"
0.5
2.5
80
30
39.6
3.1
8
84
125
IPX4
75
55
8.8-9.2
8.7-9.1
15-60
0-40
10.5-10.9
10.3-10.7
80-160
0-40
18-20
37
9 9
© Dimplex Boilers 2008

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the System 18 and is the answer not in the manual?

This manual is also suitable for:

Combi 24Combi 3830" fireplace

Table of Contents