Front Panel Interface
6.9.2
Home View (Mesa Mode)
The default view when powering on an LM Series device configured in Mesa Mode is Meter Mode > Home
View as shown in .
Home View (Mesa Mode) provides a summary of Module output gain level and limiter gain reduction, along
with frame, module and channel labeling information.
Input Meters (Mesa Mode)
Pressing the METER button from Home View in Mesa Mode will display the Input Meters View similar to
that shown in Figure 6-9. This view is not available in Contour Mode as Contour Mode Home View includes
both input and output metering information.
6.9.3
I/O Status View
Pressing the METER button from Home View (once in Contour Mode, twice in Mesa Mode) results in the
I/O Status View being displayed, similar to that shown in Figure 6-10. There are two pages to this screen;
press the meter button again to display page two. Page one displays the selected input status and metering
information for input routers 1-4, page two displays input routers 5-8.
In I/O Status View, the front panel mute button and metering LED's change to represent the Input Router
mute status an metering levels as described in 6.8.
24
Lake LM Series Operation Manual Rev 1.3.5
Figure 6-8: Meter Mode > Home View (Mesa - Module Outputs)
Figure 6-9: Meter Mode > Input Meters (Mesa Only)