INSTALLATION OF SOLAR COLLECTORS
STANDARD INSTALLATION CONTINUED
Fastening (Collectors to a Tiled Roof)
This installation is not suitable for use in cyclonic areas. For further details, please
contact your local Rinnai Solar distributor.
NOTE
•
Position the lower collector mounting rail
assembly so that the rail is angled to ensure
the collectors have an 8 mm / collector rise.
•
For aesthetic reasons it is best to mount as
close as possible to the gutter.
•
Attach the collector mounting straps to the
rafter or truss under the tiles as shown in
Figure 19.
•
Place the collector(s) onto the roof above the
lower rail. If more than one collector is being
installed then join them together using the
compression fittings supplied.
•
Push down on the collector retainers to clamp
the collector and tighten the nuts as shown in
Figure 20.
•
Position the upper collector rail above the
collectors. Push down on the retainers to
clamp the collector and tighten the nuts.
•
Attach the collector mounting straps to the
rafter or truss under the tiles as shown in
Figure 21.
•
Replace the tiles and ensure the collector is
secure as shown in Figure 22.
Rinnai Australia
Tiles removed
Nail strap to rafter
Figure 19 - Mount Lower Collector Rail
Figure 20 - Mount collector on Roof
Tiles removed
Nail strap
to rafter
Figure 21 - Attach Mounting Straps
Figure 22 - Replace Tiles
- 25 - Solar Split Systems Operating / Installation Manual - Version 9 - 21/11/12