INSTALLATION OF SOLAR COLLECTORS
STANDARD INSTALLATION CONTINUED
Fastening (Collectors to a Tiled Roof)
This installation is not suitable for use in cyclonic areas. For further details, please
contact your local Rinnai Solar distributor.
NOTE
Position the lower collector mounting rail
assembly so that the rail is angled to ensure
the collectors have an 8 mm / collector rise.
For aesthetic reasons it is best to mount as
close as possible to the gutter.
Attach the collector mounting straps to the
rafter or truss under the tiles as shown in
Figure 19.
Place the collector(s) onto the roof above the
lower rail. If more than one collector is being
installed then join them together using the
compression fittings supplied.
Push down on the collector retainers to clamp
the collector and tighten the nuts as shown in
Figure 20.
Position the upper collector rail above the
collectors. Push down on the retainers to
clamp the collector and tighten the nuts.
Attach the collector mounting straps to the
rafter or truss under the tiles as shown in
Figure 21.
Replace the tiles and ensure the collector is
secure as shown in Figure 22.
Rinnai Australia
Tiles removed
Nail strap to rafter
Figure 19 - Mount Lower Collector Rail
Figure 20 - Mount collector on Roof
Tiles removed
Nail strap
to rafter
Figure 21 - Attach Mounting Straps
Figure 22 - Replace Tiles
- 25 - Solar Split Systems Operating / Installation Manual - Version 9 - 21/11/12