Installation Manual Rinnai Split Solar Hot Water Systems - Enduro SP200B, Enduro XL SP250B and Excelsior SP200BEX Flat Plate Collectors This system shall be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3500 • All applicable local rules and regulations including local OH&S requirements This system must be installed, commissioned and serviced by an Authorised Person.
Full instructions on the installation of the complete system can be found in the “Operation / Installation Manual - Rinnai Split Solar Hot Water Systems”� All information and warnings in the “Operation / Installation Manual - Rinnai Split Solar Hot Water Systems” are applicable to this installation�...
For locations where the warranty booklet specifies collector Option B, the frost valves specified by Rinnai must be fitted and are supplied with the appropriate installation kit. Frost Protection If frost valves are missing you must obtain them and fit them.
INSTALLATION INFORMATION REGULATIONS AND OCCUPATION HEALTH AND SAFETY (OH&S) Installation and commissioning must be performed by authorised persons. Rinnai solar systems must be installed in accordance with these instructions and all regulatory requirements which exist in your area including those in relation to manual lifting, working at heights and on roofs.
Structures” in relation to these specifications. A solution may be provided using either kit DDHRKIT2 (2 collector) or DDHRKIT3 (3 collector), in accordance with the instructions in the Rinnai document “High Rise Roof Mounting Frame Installation Instructions (Part Number 15401103) StandardInstallation Installation details are in the section 'Collector Installation' on page 10.
Page 6
INSTALLATION INFORMATION Mounting Location Suitability The following table indicates which installation locations are suitable for different roof mounting options for Rinnai split solar hot water systems. Region Region Region Region Wind Region Roof Area (see page "Roof Area" Area Area...
Page 7
Area 2 Area 1 Area 3 In both examples : A = min of 0.2 x 20.3 = 4.06 0.2 x 12.1 = 2.42 1 x 3.8 = 3.8 A = 2.42 è A/2 = 1.21 m Rinnai Split Collector IM...
All hot water pipework should be insulated with sealed polyethylene foamed or equivalent insulation to optimise performance and energy efficiency, and to protect against frost damage. Such insulation may also be mandatory under local regulations. Rinnai recommend insulation to achieve at least the R value shown in the following table. Pipe between Location of Installation...
B screwing onto the Join the barrel union components together. threaded end of the header. Tighten with two spanners in the places indicated Tighten with two spanners in the places indicated in the diagram above. in the diagram above. Rinnai Split Collector IM...
Attach the collector mounting straps to the rafter or truss under the tiles. Nail strap to rafter Replace the tiles and ensure the collector is secure, and the roof is weather tight. Rinnai Split Collector IM...
Apply some silicone sealant down the holes to ensure no water leakage and secure with suitable fasteners. Alternatively the rail can be attached to the roof using the collector mounting straps. Rinnai Split Collector IM...
P.O. Box 460 Braeside, Victoria 3195 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced every 3 years.