Wiring Diagram-Wgge4324, 30, 36, 42 - Whirlpool WGGE43 Installation Instructions Manual

Package gas electric furnaces
Table of Contents

Advertisement

Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage, personal injury or death.
L1
Supply Voltage
208 -230 /1/6 0
Crankcase Heater (optional)
CC
R
T1
L1
C
COMP
S
H
CAP 1
(High)
L1
C
(Low)
L1
H
L1
D1
TRANS
L1
1
Fuse
FS
4
LS
5
ALS
3
II C
6
PS
8
ECON
9
7
10
12
11
R
G
W
Y1
To THC
See THC Field Wiring Diagram
Wiring Diagram—WGGE4324, 30, 36, 42
WARNING
HIGH VOLTAGE!
L2
T2
L2
C
CC
CAP 2
F
CM
EM
L2
VM
L2
L2
For 208 volt transformer operation,
IGN
move the black wire from Terminal
3 to Terminal 2 on transformer.
FS
RS
GV
HPS
CC
6
PL
3
C
Y/Y2
Accessory economizer plug (on select models) adjacent
to blower housing in return air compartment.
For different than factory
speed tap, change cooling
speed at Cool Terminal (IIC)
and change heating speed
at Heat Terminal (IIC).
BK - High Speed
BU - Medium High Speed
Y (4-speed motor only) - Medium Low Speed
R - Low Speed
THC Field Wiring Diagram
Some models have vent motors
equipped with a 230V lead (red)
THC - No Economizer
and a 208V (black). If equipped,
connect vent motor black lead in
place of the red lead
at IIC (DI) for 208V
operation.
2
BU
2-Stage Cooling
W
PR
BU
5
4
1
2
ALS
CAP
COMP
CM
CC
CH
EM
FS
GV
IIC
IGN
LS
PL
PS
RS
THC
TRANS
VM
W
W
G
G
BK
BU
R
R
BR
Y
Y
G
OR
C
PK
PR
R
W
W
Y
G
G
R
R
Y 1
Y
Y2
C
IMPORTANT:
Wiring is subject to change.
Always refer to the wiring
diagram on the unit for the
most up-to-date wiring.
Replacement wire must be
the same size and type of
insulation as original (use
copper conductor only).
Auxillary Limit Switch
Capacitor
Compressor
Condenser Motor
Contactor
Crankcase Heater
Evaporator Motor
Flame Sensor
Gas Control Valve
Integrated Ignition Control
Igniter
Limit Switch
Plug
Pressure Switch
Rollout Switch
Thermostat Heat and Cool
Transformer
Vent Motor
Black
Blue
Brown
Green
Orange
Pink
Purple
Red
White
Yellow
Wire Splice
Marked Terminal
Unmarked Terminal
Line Voltage
Low Voltage
Field Installed Power
Field Installed Control
29

Advertisement

Table of Contents
loading

Table of Contents